Sistema de selección en línea
Bienvenido a nuestra biblioteca completa de instrumentos y sensores. Encuentre rápidamente el producto y la solución adecuados para su aplicación. Comience con una búsqueda o elija un producto.

Technical articles are currently available in Chinese and English. English content is shown below.

← Back to knowledge hub
Measuring principles3 min readUpdated 2026-10-14

How does a Coriolis meter measure mass flow?

Understand tube vibration, mass flow, density and temperature—and why a measuring principle does not establish a model's capabilities.

Start an application checklist

Mass and volume answer different questions

Mass flow describes kilograms passing per hour; volume flow describes cubic metres passing per hour. Liquid volume can change with temperature, pressure and density, so the required quantity depends on the process or commercial objective. Coriolis measurement determines mass flow directly, but this does not mean every application is free of measurement error.

The vibrating tube provides the signal

The instrument drives its measuring tube into vibration. Fluid moving through the vibrating tube produces a Coriolis effect, creating a time or phase difference between inlet and outlet signals. Electronics use that difference to determine mass flow. Direct measurement describes the principle; calibration, installation checks and application assessment still matter.

Density and temperature are separate quantities

The resonance behaviour of a fluid-filled tube relates to fluid density and can be used to determine it. Temperature measurement helps compensate for changes in tube properties; some instruments also provide a temperature output. Available outputs, ranges and performance must be checked in the specific model's documentation.

  • Mass flow and volume flow are different display variables.
  • Density, temperature and derived concentration values are not interchangeable.

Turn the principle into application questions

First decide whether the process needs control of batch mass, delivered volume or another quantity. Supply flow range, fluid state, temperature, pressure and allowable pressure loss. Entrained gas, multiple phases and material compatibility require separate assessment. This article explains a general principle, not the suitability of a particular model.

References and further reading

Coriolis application checklist

Gather fluid, flow, pressure/temperature and installation conditions to identify missing information and engineering checks.

Start an application checklist
¿Aún no ha iniciado sesión en DOWESTON?
Cree una cuenta para empezar a seleccionar, consultar precios y recibir nuestro boletín con las últimas novedades.
Productos y servicios
Doweston ofrece una gama de servicios para ayudarle a construir rápidamente sistemas de instrumentación automatizada. Contáctenos para más información.
¿Listo para comprar?
Si desea comprar productos,
solo contacte con nuestro equipo de ventas — estaremos encantados de ayudarle.
Quiénes somos
DOWESTON ofrece soluciones de medición precisas y fiables
¡productos de detección y sensores fiables para todos los sectores!
¿Necesita servicio?
Si desea optimizar la producción y reducir los parones,
podemos ayudarle a elegir las piezas de repuesto y los productos de servicio adecuados.
Editar configuración

Producto

Marca

Modelo

Confirmar cambios Cancelar
Su pantalla puede ser demasiado pequeña para una mejor experiencia.
Le recomendamos continuar en un ordenador,
¡o contacte de inmediato con un ingeniero para su selección!
¿Servicio más rápido? Llame al
400-888-4436
Seguir navegando