How to specify minimum, normal and maximum flow

Separate stopped flow, low-flow production, normal operation and peaks instead of using one number for every condition.

Start an application checklist

Minimum flow is not the stopped condition

Specify the lowest production flow that still needs valid measurement, such as a recirculation loop, small batch or slow transfer. Describe stopped flow separately. If start-up and shutdown must also be measured, record their flow rates, durations and whether the measuring section remains full.

Normal flow describes the main operating condition

Normal flow is the most common operating point or range; it is not automatically half the maximum. If recipes, batches or seasons differ substantially, provide several typical points and their share of operating time so that comparisons represent real use.

  • For a continuous process, provide a representative flow trend.
  • For batching, provide the flow profile over time and the target batch quantity.

Separate sustained maximum from short peaks

State the maximum continuous flow and any brief peaks, such as start-up surges. Do not treat a peak as a sustained condition or disregard it solely because it is short. Check pressure loss, velocity and output range at the peak; short batches also require consideration of response and totalisation.

Use consistent units and reference conditions

An example worksheet might list minimum 100 kg/h, normal 1000 kg/h and continuous maximum 2000 kg/h, with peaks recorded separately. These are illustrative entries, not a meter rating. Gas volume needs actual or standard conditions and the reference temperature and pressure. Converting liquid volume to mass requires the density used and its associated temperature.

References and further reading

Coriolis application checklist

Gather fluid, flow, pressure/temperature and installation conditions to identify missing information and engineering checks.

Start an application checklist
¿Aún no ha iniciado sesión en DOWESTON?
Cree una cuenta para empezar a seleccionar, consultar precios y recibir nuestro boletín con las últimas novedades.
Productos y servicios
Doweston ofrece una gama de servicios para ayudarle a construir rápidamente sistemas de instrumentación automatizada. Contáctenos para más información.
¿Listo para comprar?
Si desea comprar productos,
solo contacte con nuestro equipo de ventas — estaremos encantados de ayudarle.
Quiénes somos
DOWESTON ofrece soluciones de medición precisas y fiables
¡productos de detección y sensores fiables para todos los sectores!
¿Necesita servicio?
Si desea optimizar la producción y reducir los parones,
podemos ayudarle a elegir las piezas de repuesto y los productos de servicio adecuados.
Editar configuración

Producto

Marca

Modelo

Confirmar cambios Cancelar
Su pantalla puede ser demasiado pequeña para una mejor experiencia.
Le recomendamos continuar en un ordenador,
¡o contacte de inmediato con un ingeniero para su selección!
¿Servicio más rápido? Llame al
400-888-4436
Seguir navegando