Système de sélection en ligne
Bienvenue dans notre bibliothèque complète d'instruments et de capteurs. Trouvez rapidement le produit et la solution adaptés à votre application. Commencez par une recherche ou choisissez un produit.

Technical articles are currently available in Chinese and English. English content is shown below.

← Back to knowledge hub
Measuring principles3 min readUpdated 2026-10-14

How does a Coriolis meter measure mass flow?

Understand tube vibration, mass flow, density and temperature—and why a measuring principle does not establish a model's capabilities.

Start an application checklist

Mass and volume answer different questions

Mass flow describes kilograms passing per hour; volume flow describes cubic metres passing per hour. Liquid volume can change with temperature, pressure and density, so the required quantity depends on the process or commercial objective. Coriolis measurement determines mass flow directly, but this does not mean every application is free of measurement error.

The vibrating tube provides the signal

The instrument drives its measuring tube into vibration. Fluid moving through the vibrating tube produces a Coriolis effect, creating a time or phase difference between inlet and outlet signals. Electronics use that difference to determine mass flow. Direct measurement describes the principle; calibration, installation checks and application assessment still matter.

Density and temperature are separate quantities

The resonance behaviour of a fluid-filled tube relates to fluid density and can be used to determine it. Temperature measurement helps compensate for changes in tube properties; some instruments also provide a temperature output. Available outputs, ranges and performance must be checked in the specific model's documentation.

  • Mass flow and volume flow are different display variables.
  • Density, temperature and derived concentration values are not interchangeable.

Turn the principle into application questions

First decide whether the process needs control of batch mass, delivered volume or another quantity. Supply flow range, fluid state, temperature, pressure and allowable pressure loss. Entrained gas, multiple phases and material compatibility require separate assessment. This article explains a general principle, not the suitability of a particular model.

References and further reading

Coriolis application checklist

Gather fluid, flow, pressure/temperature and installation conditions to identify missing information and engineering checks.

Start an application checklist
Pas encore connecté à DOWESTON ?
Créez un compte pour commencer la sélection, consulter les prix et recevoir notre lettre d'information sur les dernières nouveautés.
Produits et services
Doweston propose une gamme de services pour vous aider à construire rapidement vos systèmes d'instrumentation automatisés. Contactez-nous pour en savoir plus.
Prêt à acheter ?
Si vous souhaitez acheter des produits,
contactez simplement notre équipe commerciale — nous serons ravis de vous aider.
Qui sommes-nous
DOWESTON fournit des solutions de mesure précises et fiables
— des produits de détection et de capteurs fiables dans tous les domaines !
Une demande de service ?
Si vous souhaitez optimiser votre production et réduire les arrêts,
nous pouvons vous aider à choisir les pièces de rechange et les services adaptés.
Modifier la configuration

Produit

Marque

Modèle

Confirmer les modifications Annuler
Votre écran est peut-être trop petit pour une navigation optimale.
Nous vous recommandons de continuer sur un ordinateur,
ou contactez immédiatement un ingénieur pour votre sélection !
Service plus rapide ? Appelez le
400-888-4436
Continuer la navigation