Selection and applications4 min readUpdated 2026-10-14

Entrained gas, viscosity and material compatibility

A fluid name alone is insufficient: concentration, temperature, bubbles and cleaning chemicals can change the application.

Start an application checklist

Describe more than the fluid name

Provide principal components, concentration, contaminants, solids content and operating temperature and pressure. A trade name or 'mixed liquid' is insufficient for assessment. Include recipe changes and cleaning fluids. Identify whether the process is liquid, gas or may change phase.

Entrained gas is not a fixed correction

Gas bubbles in a liquid can affect the vibrating tube response and influence both mass-flow and density readings. Errors do not always act in one direction. A single calibration or universal correction factor cannot replace assessment. Record whether disturbances coincide with supply, tank-level or temperature/pressure changes, then ask an engineer to investigate.

Specify viscosity together with temperature

State viscosity value, units, associated temperature and expected variation. Independence from electrical conductivity does not remove the need to assess viscosity, pressure loss or gas content. For slurries or non-Newtonian fluids, provide solids proportion and flow behaviour so the supplier can check suitability.

  • Identify outgassing, foaming, crystallisation or settling tendencies.
  • Use data matching the actual conditions when estimating pressure loss.

Review every wetted component

Compatibility depends on composition, concentration, temperature and exposure conditions; 'stainless steel' alone is not enough. Review the measuring tube, connections, seals and any parts exposed during cleaning. Compatibility tables are reference information. Obtain confirmation for the actual fluid and configuration, and leave suitability unresolved when information is insufficient.

References and further reading

Coriolis application checklist

Gather fluid, flow, pressure/temperature and installation conditions to identify missing information and engineering checks.

Start an application checklist
¿Aún no ha iniciado sesión en DOWESTON?
Cree una cuenta para empezar a seleccionar, consultar precios y recibir nuestro boletín con las últimas novedades.
Productos y servicios
Doweston ofrece una gama de servicios para ayudarle a construir rápidamente sistemas de instrumentación automatizada. Contáctenos para más información.
¿Listo para comprar?
Si desea comprar productos,
solo contacte con nuestro equipo de ventas — estaremos encantados de ayudarle.
Quiénes somos
DOWESTON ofrece soluciones de medición precisas y fiables
¡productos de detección y sensores fiables para todos los sectores!
¿Necesita servicio?
Si desea optimizar la producción y reducir los parones,
podemos ayudarle a elegir las piezas de repuesto y los productos de servicio adecuados.
Editar configuración

Producto

Marca

Modelo

Confirmar cambios Cancelar
Su pantalla puede ser demasiado pequeña para una mejor experiencia.
Le recomendamos continuar en un ordenador,
¡o contacte de inmediato con un ingeniero para su selección!
¿Servicio más rápido? Llame al
400-888-4436
Seguir navegando