How to read accuracy, turndown and zero stability

A headline percentage may be insufficient at low flow. Compare definitions, operating ranges and test conditions.

Start an application checklist

Check what the percentage refers to

Percent of reading and percent of full scale use different reference quantities and cannot be compared directly. Look for additional fixed terms, minimum-flow conditions and fluid restrictions. Accuracy, repeatability, resolution and system uncertainty also describe different things.

Why zero stability matters at low flow

Coriolis data sheets often express zero stability in mass-flow units. At low flow, this term can become a larger proportion of the measured flow. Some manufacturers specify a low-flow calculation, but it must not be transferred to another model without verification. Turndown alone does not establish error throughout the operating range.

Compare two operating points

For illustration only, a 0.5 kg/h error term represents 0.5% of 100 kg/h and 5% of 10 kg/h. This is a ratio calculation, not a meter performance claim, and it does not replace the manufacturer's complete error model. Differences between calibration and field conditions also require assessment.

  • Request performance at minimum, normal and maximum flow.
  • Distinguish meter performance, installation effects and reference-instrument uncertainty.

Ask for evidence that supports comparison

Request performance definitions, applicable flow ranges, zero stability, fluid and temperature/pressure conditions, and calibration or verification information. For batching or commercial measurement, review the complete measurement chain and totalisation requirements. A display reading zero once is not evidence that zero stability meets a specification.

References and further reading

Coriolis application checklist

Gather fluid, flow, pressure/temperature and installation conditions to identify missing information and engineering checks.

Start an application checklist
Ещё не вошли в DOWESTON?
Создайте аккаунт, чтобы начать подбор, узнавать цены и получать рассылку о новинках и трендах.
Продукты и услуги
Doweston предлагает ряд услуг, помогающих быстро создавать системы автоматизации КИП. Свяжитесь с нами для деталей.
Готовы к покупке?
Если вы хотите приобрести продукцию,
просто свяжитесь с нашей командой продаж — мы с радостью поможем.
Кто мы
DOWESTON предлагает точные и надёжные измерительные решения
— надёжные датчики и контрольные приборы для всех отраслей!
Нужен сервис?
Если вы хотите оптимизировать производство и сократить простои,
мы поможем подобрать подходящие запчасти и сервисные продукты.
Изменить конфигурацию

Продукт

Бренд

Модель

Подтвердить изменения Отмена
Ваш экран может быть слишком мал для удобного просмотра.
Рекомендуем продолжить на компьютере
или сразу свяжитесь с инженером для подбора!
Нужен быстрый сервис? Звоните
400-888-4436
Продолжить просмотр