Des conditions du procédé au bon instrument
Comprenez les principes de mesure, vérifiez les conditions du procédé, configurez les produits et conservez vos ressources techniques.

La version française n’est pas encore disponible. La version complète en anglais est présentée ci-dessous.

← Retour à la base de connaissances
Sélection et applications3 min de lectureLangue du contenu: anglaisMis à jour 23 octobre 2026

Electromagnetic flowmeters: Can they measure oils and gases?

Oils and gases are generally nonconductive and do not meet the requirements of conventional electromagnetic flow measurement. Assess other measurement principles for these media.

Direct answer

Oils and gases are generally nonconductive and do not meet the requirements of conventional electromagnetic flow measurement. Assess other measurement principles for these media.

With no stable, continuous conductive phase, conventional electrodes cannot reliably pick up the induced voltage. Changing the units does not address that physical limitation.

What to check and when it applies

Compare actual capabilities under identical operating conditions. Check the most demanding condition separately from long-term operation to determine whether the limitation lies in the measurement, mechanical installation or interface. If candidate data use different media or reference conditions, align the assumptions before comparing. Do not combine maxima from different conditions.

The question for an electromagnetic flowmeter is whether the continuous phase is a conductive liquid. When judging interchangeability, check mechanical, electrical and functional compatibility as well as calibration pairing. Matching housings or connections establish only part of that compatibility. Record the software options and accessories actually supplied. When freezing a configuration, retain the full model, drawings and verification requirements. After maintenance, check which parts of the original configuration the replacement affected.

How to perform this check

  • First check whether the continuous phase is a conductive liquid. Record flow, electrode information and empty-pipe diagnostics. Mark which data you actually obtained. Treat undocumented diagnostics or functions as unconfirmed.
  • Tabulate the minimum, usual and most demanding operating conditions relevant to measuring the oil or gas. Indicate the duration and source of the data for each condition.
  • Compare conditions before and after checking whether the continuous phase is a conductive liquid. Select a reference suited to the equipment and conditions. Keep the original instrument configuration and process conditions during the comparison. Change only one factor at a time, guided by the evidence.

Example: how to draw a conclusion

Consider a customer asking to measure compressed air with an electromagnetic meter. If the medium under consideration is an insulating oil, increasing the current range or selecting mass units will likewise not provide the conductive path that a conventional electromagnetic meter requires.

Start by comparing the current conditions with the conditions used to select the original meter.

Confirm the findings and document the handover

The conclusion should answer whether the oil or gas can be measured. Record the evidence on whether the continuous phase is a conductive liquid, which conditions were covered, the reference used and what remains to be confirmed. Retain the original records and configuration. A single simulation at the output cannot be signed off as a pass for parts of the measurement chain that were not tested.

This is an illustrative example. Use the actual model specifications and site procedures for limits and operating conditions. Reference material does not replace Doweston supply specifications or certifications.

Appliquez ces connaissances à la sélection

Clients et achats

Vérifiez les conditions réelles et les critères de réception dans l’article et la documentation du produit. Soumettez les points ouverts au service technique DOWESTON.

Équipes commerciales et techniques

Notez les questions du client et ses conditions de service. Vérifiez la plage, les raccordements et les conditions d’utilisation dans la documentation du modèle sélectionné.

Transformez les questions en critères de sélection

Relevez le fluide, les raccordements, le montage et les critères de réception du produit, puis examinez les points ouverts avec DOWESTON.

Choisir un produit et préparer les conditions de service
Pas encore connecté à DOWESTON ?
Créez un compte pour commencer la sélection, consulter les prix et recevoir notre lettre d'information sur les dernières nouveautés.
Produits et services
Doweston propose une gamme de services pour vous aider à construire rapidement vos systèmes d'instrumentation automatisés. Contactez-nous pour en savoir plus.
Prêt à acheter ?
Si vous souhaitez acheter des produits,
contactez simplement notre équipe commerciale — nous serons ravis de vous aider.
Qui sommes-nous
DOWESTON fournit des solutions de mesure précises et fiables
— des produits de détection et de capteurs fiables dans tous les domaines !
Une demande de service ?
Si vous souhaitez optimiser votre production et réduire les arrêts,
nous pouvons vous aider à choisir les pièces de rechange et les services adaptés.
Modifier la configuration

Nom du produit

Marque

Modèle

Confirmer les modifications Annuler
Votre écran est peut-être trop petit pour une navigation optimale.
Nous vous recommandons de continuer sur un ordinateur,
ou contactez immédiatement un ingénieur pour votre sélection !
Service plus rapide ? Appelez le
400-888-4436
Continuer la navigation