La version française n’est pas encore disponible. La version complète en anglais est présentée ci-dessous.
← Retour à la base de connaissancesVibration sensors and transmitters: 50 selection, application and maintenance questions
50 shared questions for Vibration sensors and transmitters, covering selection, delivery, maintenance, common questions and evidence-based brand comparisons, with verification actions, limits and sources.
Conservez vos ressources techniques
Conservez un brouillon dans ce navigateur, puis importez-le manuellement dans votre bibliothèque après connexion.
La création de compte suit le processus habituel d’inscription et d’approbation. L’enregistrement de ressources n’ouvre pas automatiquement l’accès aux prix ni aux autres autorisations commerciales.
Shared guidance for this product family. Confirm the complete model and application; family-level guidance is not evidence of a particular product specification or approval.
Les principes généraux s’appliquent en complément de la validation du modèle. Les performances, homologations et alternatives dépendent du code de commande complet et des conditions réelles.
1What does the Vibration sensors and transmitters principle establish, and what does it not establish?
A vibration sensor measures acceleration, velocity or displacement over a defined axis and frequency band. It may output a dynamic waveform, integrated quantity or overall metric; these forms are not interchangeable. The principle explains signal generation; it does not establish the range, accuracy, materials or approvals of every model. Review the physical principle and the application limits separately.
Verification: Confirm "Whether the objective is acceleration, velocity, displacement or an overall alarm metric" and assess "Different vibration quantities and RMS/peak definitions cannot share one threshold blindly" against the actual application. Record the complete model and document revision used.
Limites d’application : Different vibration quantities and RMS/peak definitions cannot share one threshold blindly
2Is the required result measured directly or calculated from other inputs?
Define the quantity to be accepted before selecting a display unit. A vibration sensor measures acceleration, velocity or displacement over a defined axis and frequency band. It may output a dynamic waveform, integrated quantity or overall metric; these forms are not interchangeable. For "Whether the objective is acceleration, velocity, displacement or an overall alarm metric", document output definitions and conversion or compensation conditions; displaying a value does not make it a direct measurement under all conditions.
Verification: Document the process objective, units and reference conditions. Check "Using a fixed RMS-to-peak factor for arbitrary waveforms" and list separate inputs and acceptance methods for calculated results.
Limites d’application : Using a fixed RMS-to-peak factor for arbitrary waveforms
3Which application information is needed before requesting a quotation?
Prepare at least these five input groups: Whether the objective is acceleration, velocity, displacement or an overall alarm metric; Required band, speed, transients and maximum shock; Measuring direction, machine structure and mounting method; IEPE, charge, voltage, current or digital interface needs; Temperature, cabling, acquisition and diagnostic objective. Mark unknown items for confirmation instead of substituting a normal point or an assumed default for all conditions.
Verification: Have process, instrumentation and purchasing roles agree the inputs, particularly "Required band, speed, transients and maximum shock". Resolve missing evidence before requesting application confirmation.
Limites d’application : Different vibration quantities and RMS/peak definitions cannot share one threshold blindly
4How should the range be chosen rather than copied from a nominal equipment rating?
Select the range from actual operating conditions and permissible error, then check extremes and installation constraints. For this family: Different vibration quantities and RMS/peak definitions cannot share one threshold blindly Nominal size or maximum equipment rating need not equal the useful measuring interval.
Verification: List minimum, normal, maximum and abnormal conditions. Check "Measuring direction, machine structure and mounting method" against the documented performance envelope.
Limites d’application : Different vibration quantities and RMS/peak definitions cannot share one threshold blindly
5Can a larger turndown claim or display rescaling fix poor low-end performance?
No. Low-end usability depends on the principle, available signal and error mechanisms. Mounting coupling and sensor bandwidth constrain high-frequency response More display digits, software scaling or a stated turndown cannot remove the original noise or installation error.
Verification: Obtain error definitions and limits at the actual low operating point. Use "Amplitude mismatch: check units, RMS/peak, band and location" to investigate bias instead of comparing only percent-of-full-scale values.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
6How should compatibility with the measured object and materials be established?
Use the complete measured object and actual exposure, rather than a material name alone. IEPE, charge, voltage, current or digital interface needs Avoid this family-specific misuse: Connecting IEPE directly to a process-current input For non-wetted equipment, assess loads, target materials, signals and environmental compatibility instead.
Verification: List the actual contact or loading parts, seals, insulation and cleaning conditions. Have the responsible parties assess "IEPE constant-current excitation is not a 4–20 mA process loop".
Limites d’application : IEPE constant-current excitation is not a 4–20 mA process loop
7Why must abnormal and environmental conditions be listed separately from normal operation?
Normal measurement, temporary excursions and survival limits are different requirements. IEPE constant-current excitation is not a 4–20 mA process loop Start-up, cleaning, impacts, power interruption or abnormal environments can determine the necessary construction and protection.
Verification: Complete the worst-case conditions using "Temperature, cabling, acquisition and diagnostic objective" and check "Condition-monitoring output is not automatically machinery protection or safety output". Separate continuous operating limits from temporary limits in the specification.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output
8Can the published instrument accuracy be used as the installed system accuracy?
Not without assessment. Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks. The installed system also includes object, mounting, signal conversion, environmental and reference effects. Derived results additionally depend on the relevant input uncertainties.
Verification: Agree actual test points, installation conditions and the acceptance reference. Check "Choose a stiff point near the relevant bearing and mark direction" and document the system error or uncertainty basis.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
9How should response time, filtering and a stable display be balanced?
A stable indication and fast change detection involve a trade-off; filtering cannot repair incorrect installation or real process variation. Unexpected high-frequency peaks: inspect mounting resonance, cable contact and real impacts Review the complete chain when fast response matters, not merely the display refresh rate.
Verification: Define the shortest relevant event and acceptable delay. Check "Match excitation and acquisition range and allow specified settling" and verify local output, display and receiving-system response using a controlled change.
Limites d’application : Comparing high-frequency values without validating magnetic or adhesive mounting
10Which typical applications fit, and which require a specific engineering review?
Typical contexts include: Rotating-machine bearing-housing monitoring; Machine shock and vibration trending; Dynamic tests within a specified frequency band. Similar application labels do not establish equivalent conditions. In particular, assess "Condition-monitoring output is not automatically machinery protection or safety output" before relying on another installation as proof.
Verification: Select the nearest application and compare "Whether the objective is acceleration, velocity, displacement or an overall alarm metric" and "Temperature, cabling, acquisition and diagnostic objective". Obtain written confirmation where published application limits are exceeded.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output
11How should a complete order code be defined without unspecified standard options?
Translate required functions, performance and physical interfaces into verifiable options. Quantity, frequency band, axis and amplitude definition; Sensitivity, maximum input and mounting interface. Options affecting suitability or supply scope should be explicit; terms such as standard or same as existing are insufficient.
Verification: Check the complete order code and selection sheet, especially "Measuring direction, machine structure and mounting method". List accessories, documents, calibration and delivery boundaries separately.
Limites d’application : Using a fixed RMS-to-peak factor for arbitrary waveforms
12Which mounting and mechanical layout checks belong before ordering?
Choose a stiff point near the relevant bearing and mark direction The installation drawing must match the available space and process or mechanical structure. Access for fitting and servicing should be established before delivery.
Verification: Review a dimensioned, oriented site drawing. Use "IEPE, charge, voltage, current or digital interface needs" and "IEPE constant-current excitation is not a 4–20 mA process loop" to confirm connections, support, removal access and safe isolation.
Limites d’application : IEPE constant-current excitation is not a 4–20 mA process loop
13How can supporting infrastructure prevent an instrument that fits but cannot be used?
Prepare contact surface, fastening and cable strain for the mounting method Supporting conditions are part of the measurement system. Matching mechanical connections or signal names alone do not establish power, I/O, grounding or configuration compatibility.
Verification: Confirm "Excitation, bias, output and acquisition compatibility" and "Filtering, integration, overall metrics and alarm algorithm" against actual terminals, loops and receiving-system settings.
Limites d’application : Connecting IEPE directly to a process-current input
14What is a sensible commissioning sequence before changing correction factors?
Check identity, installation and basic conditions first, then status, output and process response. Match excitation and acquisition range and allow specified settling Preserve original evidence for unexplained anomalies instead of concealing them with zero or factor adjustments.
Verification: Record factory settings and initial status. Investigate "No valid waveform: check excitation, bias, cable and range" step by step and change parameters only after identifying the cause and using an authorised procedure.
Limites d’application : Comparing high-frequency values without validating magnetic or adhesive mounting
15Do identical output units or interface names establish connection compatibility?
No. Establish the represented object and reference conditions: Quantity, frequency band, axis and amplitude definition. Electrical equipment also needs loop type, scaling, failure behaviour and protocol details checked. Mechanical indicators require clear boundaries between indication and remote-transmission accessories.
Verification: Check the receiving-system variable against "Whether the objective is acceleration, velocity, displacement or an overall alarm metric" and verify limits, units and abnormal states with the actual equipment. Record wiring, configuration and end-to-end checks against "Prepare contact surface, fastening and cable strain for the mounting method".
Limites d’application : Connecting IEPE directly to a process-current input
16What should a calibration report contain to be relevant to the application?
Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks. The report should identify the delivered instrument, measured quantity, conditions, method and results. A general conformity certificate does not establish performance for every option or operating condition.
Verification: Check serial number, points, units, reference equipment and traceability. Compare "Required band, speed, transients and maximum shock" with the calibrated conditions and agree separate acceptance where they differ.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
17How can delivery and site acceptance use reproducible pass criteria?
Verify quantity, frequency band and output with a suitable vibration reference Agree criteria before testing, including range, conditions, error definition and treatment of anomalies. Similar-looking readings or an unsuitable portable reference are not sufficient acceptance evidence.
Verification: Choose an appropriate reference using "Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks.". Record "Whether the objective is acceleration, velocity, displacement or an overall alarm metric" and test conditions; investigate "Amplitude mismatch: check units, RMS/peak, band and location" before deciding on rework or recalibration.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
18What belongs in the quotation and agreement for a non-standard application?
Define why the standard supply is insufficient, the required verification and the responsible parties. Condition-monitoring output is not automatically machinery protection or safety output; Treating housing absolute vibration as relative shaft vibration. Additional materials, construction, documents or tests depend on actual requirements.
Verification: Attach "Temperature, cabling, acquisition and diagnostic objective" and the deviations. Obtain technical confirmation, additional charges, delivery conditions and acceptance methods; unknown requirements must not be assumed satisfied.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output
19Where should investigation start when there is no valid reading or output?
No valid waveform: check excitation, bias, cable and range Distinguish the actual measured condition from device-state and readout or transmission faults. Do not immediately interpret missing data as sensor failure or a zero process value.
Verification: Under appropriate safe isolation, check "Prepare contact surface, fastening and cable strain for the mounting method". Compare local and receiving-end status and record when the fault appeared.
Limites d’application : Using a fixed RMS-to-peak factor for arbitrary waveforms
20How can unstable readings be separated from genuine process variation?
Unexpected high-frequency peaks: inspect mounting resonance, cable contact and real impacts Compare independent process evidence and raw signals before deciding whether installation, interference or equipment is responsible. More filtering can hide a real abnormal event.
Verification: Keep conditions comparable and record correlation with process or equipment events. Check "Choose a stiff point near the relevant bearing and mark direction" and change one factor at a time.
Limites d’application : Comparing high-frequency values without validating magnetic or adhesive mounting
21How should a persistent high or low bias be investigated before changing factors?
Amplitude mismatch: check units, RMS/peak, band and location Systematic bias can arise from units, reference conditions, configuration, installation or the reference method. An unexplained correction can move one operating-point error to other conditions.
Verification: Align quantities, time bases and units first. Review the reference using "Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks." and confirm that "Required band, speed, transients and maximum shock" matches the configuration.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
22When is it appropriate to adjust a drifting zero or reference position?
Low-frequency drift: check integration, coupling cutoff and baseline noise Establish a genuine, stable reference condition that meets the method requirements before considering adjustment. Some instruments have no freely adjustable site zero.
Verification: Check "Match excitation and acquisition range and allow specified settling" and "Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks." and retain before-and-after results. If the conditions cannot be established, remove external effects or use a qualified service.
Limites d’application : Comparing high-frequency values without validating magnetic or adhesive mounting
23Which evidence helps diagnose intermittent alarms or failures?
Intermittent overload: check shock peaks, excitation headroom and connectors Intermittent faults need correlated event records, not just a normal display after recovery. Review alarm settings, communication status and actual process abnormalities separately.
Verification: Retain time, status codes, raw trends and the contemporaneous "Temperature, cabling, acquisition and diagnostic objective". Compare "Prepare contact surface, fastening and cable strain for the mounting method" and "Match excitation and acquisition range and allow specified settling" to locate the failing link.
Limites d’application : Treating housing absolute vibration as relative shaft vibration
24Why should repeated failures trigger a cause review instead of another identical replacement?
Repeated failures warrant a common-cause assessment. Treating housing absolute vibration as relative shaft vibration If the external conditions remain unchanged, an identical construction or installation can experience the same failure again.
Verification: Summarise failed parts, service time and "Temperature, cabling, acquisition and diagnostic objective". Check "Choose a stiff point near the relevant bearing and mark direction" and "IEPE constant-current excitation is not a 4–20 mA process loop" and establish corrective action before selecting repair or redesign.
Limites d’application : IEPE constant-current excitation is not a 4–20 mA process loop
25What distinguishes a site comparison, an adjustment and a calibration?
Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks. A comparison identifies differences; adjustment changes indication or parameters; calibration establishes a reference relationship under stated conditions. They are not interchangeable claims.
Verification: Define what performance and evidence must be established, using conditions relevant to "Required band, speed, transients and maximum shock". Retain original and adjusted results, references and responsibility records.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
26What must be checked again after replacing an instrument with the same basic model?
The same basic model does not establish identical options, software, calibration or accessories. Filtering, integration, overall metrics and alarm algorithm; Environmental, calibration and protection-duty evidence. Previous system operation does not remove the need to verify a replacement.
Verification: Compare full order codes and revisions. Recheck critical points, failure states and interfaces using "Verify quantity, frequency band and output with a suitable vibration reference" before handover.
Limites d’application : Treating housing absolute vibration as relative shaft vibration
27Can every published maximum rating be achieved simultaneously?
No. Different vibration quantities and RMS/peak definitions cannot share one threshold blindly Maximum values usually relate to particular options and conditions. Temperature, load, pressure, materials, speed or signal conditions may constrain one another.
Verification: Review "Measuring direction, machine structure and mounting method" and "Temperature, cabling, acquisition and diagnostic objective" together. Obtain confirmation for the combined conditions instead of assembling unrelated maxima from separate pages.
Limites d’application : Different vibration quantities and RMS/peak definitions cannot share one threshold blindly
28Does a missing signal or zero indication establish that the process value is zero?
No. No valid waveform: check excitation, bias, cable and range Indication, measurement and transmission have distinct possible failure modes. Also consider "Using a fixed RMS-to-peak factor for arbitrary waveforms"; establish the actual process condition independently.
Verification: Check available status or failure indications and "Excitation, bias, output and acquisition compatibility". For interlocks, follow the complete safety design rather than substituting a zero value for diagnosis.
Limites d’application : Using a fixed RMS-to-peak factor for arbitrary waveforms
29Does one acceptable test point establish compliance across the working range?
No. Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks. Test points and directions must reflect the working interval, relevant error mechanisms and acceptance purpose. Multiple points, reversal or load tests depend on the method.
Verification: Define acceptance coverage against "Required band, speed, transients and maximum shock" and include critical operating points. Mark conditions outside the tests as unverified.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
30Are the largest range, highest accuracy class and most options always preferable?
Not necessarily. Options should serve the required objective; excess configuration can add cost, complexity or incompatibility. Mounting coupling and sensor bandwidth constrain high-frequency response; Connecting IEPE directly to a process-current input. Establish essential requirements before comparing optional benefits.
Verification: Document the objective in "Whether the objective is acceleration, velocity, displacement or an overall alarm metric" and why "Quantity, frequency band, axis and amplitude definition" is needed. Compare performance at actual working points rather than one headline metric.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
31Can every maintenance or recalibration interval simply be fixed at one year?
Not independently of risk and history. Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks. Intervals depend on applicable law or contract, conditions, drift, maintenance and failure evidence. Generic advice cannot replace mandatory requirements.
Verification: Use "Low-frequency drift: check integration, coupling cutoff and baseline noise" and "Treating housing absolute vibration as relative shaft vibration" to establish and review an initial plan. Retain the justification and approval for interval changes.
Limites d’application : Treating housing absolute vibration as relative shaft vibration
32Can parts from different brands be mixed if their physical interfaces fit?
Physical fit is insufficient. Sensitivity, maximum input and mounting interface; Excitation, bias, output and acquisition compatibility. Matching, materials, signals, calibration and approval boundaries can change with the combination.
Verification: Check the complete combination against "Prepare contact surface, fastening and cable strain for the mounting method" and obtain compatibility and acceptance evidence. An unconfirmed assembly must not be described as an approved system.
Limites d’application : Connecting IEPE directly to a process-current input
33Does a hazardous-area, hygienic or safety label establish suitability for that duty?
Check the exact order configuration and valid documents rather than a series name. Environmental, calibration and protection-duty evidence "Condition-monitoring output is not automatically machinery protection or safety output" also matters; certificates, installation conditions and restrictions together define suitability.
Verification: Obtain certificate identifiers, covered models and special conditions and match them to the site. Similar names do not grant functional-safety or legal-metrology approval.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output
34What evidence makes the final result acceptable, reproducible and sustainable?
Establish the chain from quantity definition and application limits through configuration, mounting, reference and operating status. Verify quantity, frequency band and output with a suitable vibration reference A normal indication or brochure alone cannot demonstrate continuing system reliability.
Verification: Put "Whether the objective is acceleration, velocity, displacement or an overall alarm metric", "Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks." and "Intermittent overload: check shock peaks, excitation headroom and connectors" into the technical, acceptance and maintenance records, with responsibility for reviewing excursions.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output
35Can a DOWESTON model replace an installed instrument from another brand?
Possibly, after a full configuration and application comparison. A basic model name or matching output is not proof of equivalent replacement. Quantity, frequency band, axis and amplitude definition; Sensitivity, maximum input and mounting interface; Excitation, bias, output and acquisition compatibility. Record conclusions on material differences.
Verification: Provide the original full order code, data sheet and site conditions. Check "Filtering, integration, overall metrics and alarm algorithm" and "Environmental, calibration and protection-duty evidence" and obtain the necessary test and approval evidence before replacement.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output
36Why choose DOWESTON, and what would make that reasoning evidence-based?
Base the decision on project compliance and documented delivery or service, rather than a slogan. "Whether the objective is acceleration, velocity, displacement or an overall alarm metric" and "Different vibration quantities and RMS/peak definitions cannot share one threshold blindly" are important family-specific checks. Claim only benefits supported by the offered product documents and written commitments.
Verification: Request the proposed configuration matching "Quantity, frequency band, axis and amplitude definition", test evidence and delivery/service terms. Do not infer unverified performance, approvals, origin or service life.
Limites d’application : Different vibration quantities and RMS/peak definitions cannot share one threshold blindly
37How can competing brands be compared beyond a single accuracy or price figure?
Use identical conditions and supply boundaries. Quantity, frequency band, axis and amplitude definition; Excitation, bias, output and acquisition compatibility; Environmental, calibration and protection-duty evidence. Quotes with different ranges, compensation, accessories or calibration scope can conceal material differences.
Verification: Compare "Required band, speed, transients and maximum shock", "Mounting coupling and sensor bandwidth constrain high-frequency response" and mounting/acceptance conditions. Separate demonstrated, unverified and inapplicable items; do not claim unproven overall superiority.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
38How should purchasing compare cost without overlooking additions or rework?
Compare complete supply and use-cycle costs, not only the main instrument price. Choose a stiff point near the relevant bearing and mark direction; Vibration calibration must state quantity, axis, frequency, amplitude and mounting; one sensitivity point does not establish the whole bandwidth, and waveforms and overall metrics need separate checks. List the actual installation, supporting equipment, calibration, consumables, downtime and service requirements without assuming any brand is always cheaper.
Verification: Use the same "Quantity, frequency band, axis and amplitude definition" configuration and "Temperature, cabling, acquisition and diagnostic objective" boundary. Separate equipment, accessories, commissioning and maintenance responsibilities and retain a traceable comparison.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output
39Can acceleration, velocity and displacement values be compared directly?
No. They are different quantities. Single-frequency sinusoids permit angular-frequency conversion, but broadband and impact signals require defined bands and integration.
Verification: Check units, band and waveform and record integration and high-pass settings before comparison.
Limites d’application : Different vibration quantities and RMS/peak definitions cannot share one threshold blindly
40Does RMS multiplied by square root of two always give peak amplitude?
That relationship applies to a sinusoid under the relevant definition, not every waveform. Impulsive, harmonic or random vibration can have different crest factors.
Verification: Retain the waveform and definitions and compute RMS, peak and peak-to-peak over a stated window.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
41Why should an IEPE accelerometer not be connected directly to a 4–20 mA input?
IEPE uses specified constant-current excitation with a dynamic voltage on a bias. Process-current input power and scaling are different despite similar current numbers.
Verification: Verify excitation, DAQ IEPE capability, bias headroom and cable loading before wiring.
Limites d’application : IEPE constant-current excitation is not a 4–20 mA process loop
42Can a piezoelectric accelerometer measure static tilt or sustained DC acceleration?
Dynamic piezoelectric measurement normally has a low-frequency cutoff and is not a direct sustained-DC measurement; a different technology may support DC, subject to model evidence.
Verification: Define static versus dynamic duty, check principle and low-frequency limit and validate with an appropriate reference.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output
43Does magnetic mounting preserve stud-mount high-frequency response?
Not automatically. A magnet, adhesive layer and surface condition change coupling stiffness and mounting resonance, affecting high-frequency amplitude.
Verification: Check mounting response over the target band and compare at a consistent prepared location.
Limites d’application : Different vibration quantities and RMS/peak definitions cannot share one threshold blindly
44Why can integration of acceleration produce low-frequency drift?
Integration amplifies low-frequency offset and noise effects; coupling, detrending and high-pass settings alter the result and require a justified lower band limit.
Verification: Retain acceleration, inspect baseline and lower-band settings and compare with a suitable velocity reference.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
45Does saturation for a few seconds after powering prove sensor damage?
Not necessarily. IEPE sensors and conditioning may require specified settling; connection transients affect data. Observe the documented settling period before using samples.
Verification: Check settling specifications and bias recovery; investigate supply, cable and range if the anomaly persists.
Limites d’application : IEPE constant-current excitation is not a 4–20 mA process loop
46What should be checked first when two vibration instruments disagree?
Align point, axis, mounting, band, quantity and RMS/peak definition; windows and overall algorithms also affect results. The same machine does not guarantee the same measurand.
Verification: Test synchronously with comparable locations and settings and retain waveforms and configuration.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output
47Can bearing-housing vibration replace relative shaft vibration?
No. Housing vibration and shaft-to-probe relative motion describe different relationships; support and rotor dynamics determine how they relate.
Verification: Identify the OEM-required quantity and location and do not copy thresholds between them.
Limites d’application : Different vibration quantities and RMS/peak definitions cannot share one threshold blindly
48Why can a normal overall vibration value coexist with a local bearing fault?
An overall metric is limited by its band and averaging. Local impacts or modulation may contribute little total energy; detection depends on sensing and analysis capability.
Verification: Review bandwidth, waveform and suitable analysis for the target fault rather than treating one overall value as complete health evidence.
Limites d’application : Mounting coupling and sensor bandwidth constrain high-frequency response
49Can a generic online vibration threshold be copied directly?
No. Machine class, support, quantity, band and operating state differ, as can applicable standards or OEM requirements; a generic number does not establish suitability.
Verification: Document the basis and baseline and obtain approval and verification of thresholds and delays.
Limites d’application : IEPE constant-current excitation is not a 4–20 mA process loop
50Does a higher sample rate always improve vibration diagnosis?
No. Sensor/mounting bandwidth, anti-aliasing, duration and noise also matter. Sampling beyond useful bandwidth adds no genuine information, and frequency resolution depends on record length.
Verification: Choose rate and duration for the target band and low frequency and verify anti-aliasing and channel capability.
Limites d’application : Condition-monitoring output is not automatically machinery protection or safety output






