Des conditions du procédé au bon instrument
Comprenez les principes de mesure, vérifiez les conditions du procédé, configurez les produits et conservez vos ressources techniques.

La version française n’est pas encore disponible. La version complète en anglais est présentée ci-dessous.

← Retour à la base de connaissances
Sélection et applications3 min de lectureLangue du contenu: anglaisMis à jour 23 octobre 2026

How should electrodes be oriented when mounting an electromagnetic flowmeter horizontally?

For horizontal installation, keep electrodes away from locations where gas or deposits can collect. Check the allowed orientation in the manual for the model.

Keep the electrodes in reliable contact with the liquid

For horizontal installation, keep electrodes away from locations where gas or deposits can collect. Check the allowed orientation in the manual for the model.

An electrode at the crown can come into contact with trapped gas. An electrode at the bottom can be covered by sediment. Position the instrument within the orientations permitted by the manufacturer.

Check local conditions at the sensing point

The conductive liquid, electrode interfaces and reference connection form the path of the weak measuring signal. First check continuous electrical contact with the liquid. Then inspect electrode fouling or a changed reference. Readings during one process stage show that a signal exists at that stage. They do not guarantee the same signal margin throughout the cycle.

Check the electrode axis against the installation drawing. Conditions at the sensing point may differ from conditions in the bulk liquid. Conductive, dielectric and optical sensors respond to different material properties. Bridging, retained films and insulating deposits can change responses in opposite directions. A liquid trial should cover both wetting and residual liquid after drainage. A demonstration with clean water or a simulated signal cannot represent all actual operating conditions.

Field checks

  • Verify the electrode axis on the installation drawing. Record flow readings and any available electrode or empty-pipe diagnostics. Separate the measurements captured from functions the instrument does not support.
  • Record the minimum, typical and most unfavorable operating conditions that affect the electrode position. State their duration and the source of the observations.
  • Document the electrode axis and the installation drawing before and after checking orientation. Preserve the original setup and process conditions and change one factor at a time based on the evidence.

Example: gas collecting at the top of a horizontal pipe

Suppose bubbles at the pipe crown contact a top-mounted electrode. Check the orientations permitted for the model and retest under the actual filling conditions before concluding that a side orientation improves the readings.

Compare the observed conditions with the original basis for selection.

Record the orientation and the result

Support your conclusion with the electrode axis on the sensor installation drawing. Record the conditions tested, the comparison basis and any open items. Retain the original orientation and configuration. An output simulation cannot verify parts of the measuring chain it bypasses.

This is an illustrative case. Follow the limits of the installed model and the site procedures. Use Doweston’s supply documents to confirm equipment specifications and certification.

Appliquez ces connaissances à la sélection

Clients et achats

Vérifiez les conditions réelles et les critères de réception dans l’article et la documentation du produit. Soumettez les points ouverts au service technique DOWESTON.

Équipes commerciales et techniques

Notez les questions du client et ses conditions de service. Vérifiez la plage, les raccordements et les conditions d’utilisation dans la documentation du modèle sélectionné.

Transformez les questions en critères de sélection

Relevez le fluide, les raccordements, le montage et les critères de réception du produit, puis examinez les points ouverts avec DOWESTON.

Choisir un produit et préparer les conditions de service
Pas encore connecté à DOWESTON ?
Créez un compte pour commencer la sélection, consulter les prix et recevoir notre lettre d'information sur les dernières nouveautés.
Produits et services
Doweston propose une gamme de services pour vous aider à construire rapidement vos systèmes d'instrumentation automatisés. Contactez-nous pour en savoir plus.
Prêt à acheter ?
Si vous souhaitez acheter des produits,
contactez simplement notre équipe commerciale — nous serons ravis de vous aider.
Qui sommes-nous
DOWESTON fournit des solutions de mesure précises et fiables
— des produits de détection et de capteurs fiables dans tous les domaines !
Une demande de service ?
Si vous souhaitez optimiser votre production et réduire les arrêts,
nous pouvons vous aider à choisir les pièces de rechange et les services adaptés.
Modifier la configuration

Nom du produit

Marque

Modèle

Confirmer les modifications Annuler
Votre écran est peut-être trop petit pour une navigation optimale.
Nous vous recommandons de continuer sur un ordinateur,
ou contactez immédiatement un ingénieur pour votre sélection !
Service plus rapide ? Appelez le
400-888-4436
Continuer la navigation