La version française n’est pas encore disponible. La version complète en anglais est présentée ci-dessous.
← Retour à la base de connaissancesCapacitance level measurement: 50 selection, application and maintenance questions
50 shared questions for Capacitance level measurement, covering selection, delivery, maintenance, common questions and evidence-based brand comparisons, with verification actions, limits and sources.
Conservez vos ressources techniques
Conservez un brouillon dans ce navigateur, puis importez-le manuellement dans votre bibliothèque après connexion.
La création de compte suit le processus habituel d’inscription et d’approbation. L’enregistrement de ressources n’ouvre pas automatiquement l’accès aux prix ni aux autres autorisations commerciales.
Shared guidance for this product family. Confirm the complete model and application; family-level guidance is not evidence of a particular product specification or approval.
Les principes généraux s’appliquent en complément de la validation du modèle. Les performances, homologations et alternatives dépendent du code de commande complet et des conditions réelles.
1What does the Capacitance level measurement principle establish, and what does it not establish?
A probe and reference form a capacitor; coverage and media properties change the signal for level or point detection. The principle explains signal generation; it does not establish the range, accuracy, materials or approvals of every model. Review the physical principle and the application limits separately.
Verification: Confirm "Permittivity and conductivity" and assess "Permittivity changes can affect calibration" against the actual application. Record the complete model and document revision used.
Limites d’application : Permittivity changes can affect calibration
2Is the required result measured directly or calculated from other inputs?
Define the quantity to be accepted before selecting a display unit. A probe and reference form a capacitor; coverage and media properties change the signal for level or point detection. For "Permittivity and conductivity", document output definitions and conversion or compensation conditions; displaying a value does not make it a direct measurement under all conditions.
Verification: Document the process objective, units and reference conditions. Check "Permittivity changes can affect calibration" and list separate inputs and acceptance methods for calculated results.
Limites d’application : Permittivity changes can affect calibration
3Which application information is needed before requesting a quotation?
Prepare at least these five input groups: Permittivity and conductivity; Vessel material and grounding; Probe type, length and coverage; Buildup, crystallization and tension; Continuous or point output. Mark unknown items for confirmation instead of substituting a normal point or an assumed default for all conditions.
Verification: Have process, instrumentation and purchasing roles agree the inputs, particularly "Vessel material and grounding". Resolve missing evidence before requesting application confirmation.
Limites d’application : Permittivity changes can affect calibration
4How should the range be chosen rather than copied from a nominal equipment rating?
Select the range from actual operating conditions and permissible error, then check extremes and installation constraints. For this family: Permittivity changes can affect calibration Nominal size or maximum equipment rating need not equal the useful measuring interval.
Verification: List minimum, normal, maximum and abnormal conditions. Check "Probe type, length and coverage" against the documented performance envelope.
Limites d’application : Permittivity changes can affect calibration
5Can a larger turndown claim or display rescaling fix poor low-end performance?
No. Low-end usability depends on the principle, available signal and error mechanisms. Coating compensation needs exact-model evidence More display digits, software scaling or a stated turndown cannot remove the original noise or installation error.
Verification: Obtain error definitions and limits at the actual low operating point. Use "Why not compensate insulation damage with a threshold → Leakage is uncontrolled and variable; threshold adjustment cannot restore insulation. → Confirm reference electrode and grounding and record Buildup, crystallization and tension" to investigate bias instead of comparing only percent-of-full-scale values.
Limites d’application : Coating compensation needs exact-model evidence
6How should compatibility with the measured object and materials be established?
Use the complete measured object and actual exposure, rather than a material name alone. Buildup, crystallization and tension Avoid this family-specific misuse: Coating compensation needs exact-model evidence For non-wetted equipment, assess loads, target materials, signals and environmental compatibility instead.
Verification: List the actual contact or loading parts, seals, insulation and cleaning conditions. Have the responsible parties assess "Probe contact with the wall can invalidate measurement".
Limites d’application : Probe contact with the wall can invalidate measurement
7Why must abnormal and environmental conditions be listed separately from normal operation?
Normal measurement, temporary excursions and survival limits are different requirements. Probe contact with the wall can invalidate measurement Start-up, cleaning, impacts, power interruption or abnormal environments can determine the necessary construction and protection.
Verification: Complete the worst-case conditions using "Continuous or point output" and check "Capacitance percentage is not necessarily volume percentage". Separate continuous operating limits from temporary limits in the specification.
Limites d’application : Capacitance percentage is not necessarily volume percentage
8Can the published instrument accuracy be used as the installed system accuracy?
Not without assessment. Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. The installed system also includes object, mounting, signal conversion, environmental and reference effects. Derived results additionally depend on the relevant input uncertainties.
Verification: Agree actual test points, installation conditions and the acceptance reference. Check "Confirm reference electrode and grounding" and document the system error or uncertainty basis.
Limites d’application : Coating compensation needs exact-model evidence
9How should response time, filtering and a stable display be balanced?
A stable indication and fast change detection involve a trade-off; filtering cannot repair incorrect installation or real process variation. Does temperature-related shift prove electronic drift → No. Media electrical properties can change with temperature. → Avoid impact and excessive tensile loading and record Probe type, length and coverage Review the complete chain when fast response matters, not merely the display refresh rate.
Verification: Define the shortest relevant event and acceptable delay. Check "Check empty/full response with actual media" and verify local output, display and receiving-system response using a controlled change.
Limites d’application : Probe contact with the wall can invalidate measurement
10Which typical applications fit, and which require a specific engineering review?
Typical contexts include: Continuous tank level; Powder high/low limits; Application-specific viscous service. Similar application labels do not establish equivalent conditions. In particular, assess "Capacitance percentage is not necessarily volume percentage" before relying on another installation as proof.
Verification: Select the nearest application and compare "Permittivity and conductivity" and "Continuous or point output". Obtain written confirmation where published application limits are exceeded.
Limites d’application : Capacitance percentage is not necessarily volume percentage
11How should a complete order code be defined without unspecified standard options?
Translate required functions, performance and physical interfaces into verifiable options. Permittivity and conductivity; Vessel material and grounding. Options affecting suitability or supply scope should be explicit; terms such as standard or same as existing are insufficient.
Verification: Check the complete order code and selection sheet, especially "Probe type, length and coverage". List accessories, documents, calibration and delivery boundaries separately.
Limites d’application : Permittivity changes can affect calibration
12Which mounting and mechanical layout checks belong before ordering?
Confirm reference electrode and grounding The installation drawing must match the available space and process or mechanical structure. Access for fitting and servicing should be established before delivery.
Verification: Review a dimensioned, oriented site drawing. Use "Buildup, crystallization and tension" and "Probe contact with the wall can invalidate measurement" to confirm connections, support, removal access and safe isolation.
Limites d’application : Probe contact with the wall can invalidate measurement
13How can supporting infrastructure prevent an instrument that fits but cannot be used?
Maintain probe-to-wall clearance Supporting conditions are part of the measurement system. Matching mechanical connections or signal names alone do not establish power, I/O, grounding or configuration compatibility.
Verification: Confirm "Confirm reference electrode and grounding" and "Verify output, failure state and receiving-system compatibility" against actual terminals, loops and receiving-system settings.
Limites d’application : Coating compensation needs exact-model evidence
14What is a sensible commissioning sequence before changing correction factors?
Check identity, installation and basic conditions first, then status, output and process response. Check empty/full response with actual media Preserve original evidence for unexplained anomalies instead of concealing them with zero or factor adjustments.
Verification: Record factory settings and initial status. Investigate "What causes a high empty indication → Coating, moisture, grounding or residue can shift the baseline. → Check empty/full response with actual media and record Vessel material and grounding" step by step and change parameters only after identifying the cause and using an authorised procedure.
Limites d’application : Probe contact with the wall can invalidate measurement
15Do identical output units or interface names establish connection compatibility?
No. Establish the represented object and reference conditions: Permittivity and conductivity. Electrical equipment also needs loop type, scaling, failure behaviour and protocol details checked. Mechanical indicators require clear boundaries between indication and remote-transmission accessories.
Verification: Check the receiving-system variable against "Permittivity and conductivity" and verify limits, units and abnormal states with the actual equipment. Record wiring, configuration and end-to-end checks against "Maintain probe-to-wall clearance".
Limites d’application : Coating compensation needs exact-model evidence
16What should a calibration report contain to be relevant to the application?
Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. The report should identify the delivered instrument, measured quantity, conditions, method and results. A general conformity certificate does not establish performance for every option or operating condition.
Verification: Check serial number, points, units, reference equipment and traceability. Compare "Vessel material and grounding" with the calibrated conditions and agree separate acceptance where they differ.
Limites d’application : Coating compensation needs exact-model evidence
17How can delivery and site acceptance use reproducible pass criteria?
Avoid impact and excessive tensile loading Agree criteria before testing, including range, conditions, error definition and treatment of anomalies. Similar-looking readings or an unsuitable portable reference are not sufficient acceptance evidence.
Verification: Choose an appropriate reference using "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment.". Record "Permittivity and conductivity" and test conditions; investigate "Why not compensate insulation damage with a threshold → Leakage is uncontrolled and variable; threshold adjustment cannot restore insulation. → Confirm reference electrode and grounding and record Buildup, crystallization and tension" before deciding on rework or recalibration.
Limites d’application : Coating compensation needs exact-model evidence
18What belongs in the quotation and agreement for a non-standard application?
Define why the standard supply is insufficient, the required verification and the responsible parties. Capacitance percentage is not necessarily volume percentage; Capacitance percentage is not necessarily volume percentage. Additional materials, construction, documents or tests depend on actual requirements.
Verification: Attach "Continuous or point output" and the deviations. Obtain technical confirmation, additional charges, delivery conditions and acceptance methods; unknown requirements must not be assumed satisfied.
Limites d’application : Capacitance percentage is not necessarily volume percentage
19Where should investigation start when there is no valid reading or output?
What causes a high empty indication → Coating, moisture, grounding or residue can shift the baseline. → Check empty/full response with actual media and record Vessel material and grounding Distinguish the actual measured condition from device-state and readout or transmission faults. Do not immediately interpret missing data as sensor failure or a zero process value.
Verification: Under appropriate safe isolation, check "Maintain probe-to-wall clearance". Compare local and receiving-end status and record when the fault appeared.
Limites d’application : Permittivity changes can affect calibration
20How can unstable readings be separated from genuine process variation?
Does temperature-related shift prove electronic drift → No. Media electrical properties can change with temperature. → Avoid impact and excessive tensile loading and record Probe type, length and coverage Compare independent process evidence and raw signals before deciding whether installation, interference or equipment is responsible. More filtering can hide a real abnormal event.
Verification: Keep conditions comparable and record correlation with process or equipment events. Check "Confirm reference electrode and grounding" and change one factor at a time.
Limites d’application : Probe contact with the wall can invalidate measurement
21How should a persistent high or low bias be investigated before changing factors?
Why not compensate insulation damage with a threshold → Leakage is uncontrolled and variable; threshold adjustment cannot restore insulation. → Confirm reference electrode and grounding and record Buildup, crystallization and tension Systematic bias can arise from units, reference conditions, configuration, installation or the reference method. An unexplained correction can move one operating-point error to other conditions.
Verification: Align quantities, time bases and units first. Review the reference using "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment." and confirm that "Vessel material and grounding" matches the configuration.
Limites d’application : Coating compensation needs exact-model evidence
22When is it appropriate to adjust a drifting zero or reference position?
Does linear output imply linear vessel volume → No. Level-to-volume geometry must be modeled separately. → Maintain probe-to-wall clearance and record Continuous or point output Establish a genuine, stable reference condition that meets the method requirements before considering adjustment. Some instruments have no freely adjustable site zero.
Verification: Check "Check empty/full response with actual media" and "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment." and retain before-and-after results. If the conditions cannot be established, remove external effects or use a qualified service.
Limites d’application : Probe contact with the wall can invalidate measurement
23Which evidence helps diagnose intermittent alarms or failures?
Can sensitivity be raised without limit for light dielectric material → No. Adequate contrast and noise margin are still necessary. → Check empty/full response with actual media and record Permittivity and conductivity Intermittent faults need correlated event records, not just a normal display after recovery. Review alarm settings, communication status and actual process abnormalities separately.
Verification: Retain time, status codes, raw trends and the contemporaneous "Continuous or point output". Compare "Maintain probe-to-wall clearance" and "Check empty/full response with actual media" to locate the failing link.
Limites d’application : Capacitance percentage is not necessarily volume percentage
24Why should repeated failures trigger a cause review instead of another identical replacement?
Repeated failures warrant a common-cause assessment. Capacitance percentage is not necessarily volume percentage If the external conditions remain unchanged, an identical construction or installation can experience the same failure again.
Verification: Summarise failed parts, service time and "Continuous or point output". Check "Confirm reference electrode and grounding" and "Probe contact with the wall can invalidate measurement" and establish corrective action before selecting repair or redesign.
Limites d’application : Probe contact with the wall can invalidate measurement
25What distinguishes a site comparison, an adjustment and a calibration?
Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. A comparison identifies differences; adjustment changes indication or parameters; calibration establishes a reference relationship under stated conditions. They are not interchangeable claims.
Verification: Define what performance and evidence must be established, using conditions relevant to "Vessel material and grounding". Retain original and adjusted results, references and responsibility records.
Limites d’application : Coating compensation needs exact-model evidence
26What must be checked again after replacing an instrument with the same basic model?
The same basic model does not establish identical options, software, calibration or accessories. Verify output, failure state and receiving-system compatibility; Confirm certificates, calibration and site change approval in writing. Previous system operation does not remove the need to verify a replacement.
Verification: Compare full order codes and revisions. Recheck critical points, failure states and interfaces using "Avoid impact and excessive tensile loading" before handover.
Limites d’application : Capacitance percentage is not necessarily volume percentage
27Can every published maximum rating be achieved simultaneously?
No. Permittivity changes can affect calibration Maximum values usually relate to particular options and conditions. Temperature, load, pressure, materials, speed or signal conditions may constrain one another.
Verification: Review "Probe type, length and coverage" and "Continuous or point output" together. Obtain confirmation for the combined conditions instead of assembling unrelated maxima from separate pages.
Limites d’application : Permittivity changes can affect calibration
28Does a missing signal or zero indication establish that the process value is zero?
No. What causes a high empty indication → Coating, moisture, grounding or residue can shift the baseline. → Check empty/full response with actual media and record Vessel material and grounding Indication, measurement and transmission have distinct possible failure modes. Also consider "Permittivity changes can affect calibration"; establish the actual process condition independently.
Verification: Check available status or failure indications and "Confirm reference electrode and grounding". For interlocks, follow the complete safety design rather than substituting a zero value for diagnosis.
Limites d’application : Permittivity changes can affect calibration
29Does one acceptable test point establish compliance across the working range?
No. Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. Test points and directions must reflect the working interval, relevant error mechanisms and acceptance purpose. Multiple points, reversal or load tests depend on the method.
Verification: Define acceptance coverage against "Vessel material and grounding" and include critical operating points. Mark conditions outside the tests as unverified.
Limites d’application : Coating compensation needs exact-model evidence
30Are the largest range, highest accuracy class and most options always preferable?
Not necessarily. Options should serve the required objective; excess configuration can add cost, complexity or incompatibility. Coating compensation needs exact-model evidence; Coating compensation needs exact-model evidence. Establish essential requirements before comparing optional benefits.
Verification: Document the objective in "Permittivity and conductivity" and why "Permittivity and conductivity" is needed. Compare performance at actual working points rather than one headline metric.
Limites d’application : Coating compensation needs exact-model evidence
31Can every maintenance or recalibration interval simply be fixed at one year?
Not independently of risk and history. Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. Intervals depend on applicable law or contract, conditions, drift, maintenance and failure evidence. Generic advice cannot replace mandatory requirements.
Verification: Use "Does linear output imply linear vessel volume → No. Level-to-volume geometry must be modeled separately. → Maintain probe-to-wall clearance and record Continuous or point output" and "Capacitance percentage is not necessarily volume percentage" to establish and review an initial plan. Retain the justification and approval for interval changes.
Limites d’application : Capacitance percentage is not necessarily volume percentage
32Can parts from different brands be mixed if their physical interfaces fit?
Physical fit is insufficient. Vessel material and grounding; Confirm reference electrode and grounding. Matching, materials, signals, calibration and approval boundaries can change with the combination.
Verification: Check the complete combination against "Maintain probe-to-wall clearance" and obtain compatibility and acceptance evidence. An unconfirmed assembly must not be described as an approved system.
Limites d’application : Coating compensation needs exact-model evidence
33Does a hazardous-area, hygienic or safety label establish suitability for that duty?
Check the exact order configuration and valid documents rather than a series name. Confirm certificates, calibration and site change approval in writing "Capacitance percentage is not necessarily volume percentage" also matters; certificates, installation conditions and restrictions together define suitability.
Verification: Obtain certificate identifiers, covered models and special conditions and match them to the site. Similar names do not grant functional-safety or legal-metrology approval.
Limites d’application : Capacitance percentage is not necessarily volume percentage
34What evidence makes the final result acceptable, reproducible and sustainable?
Establish the chain from quantity definition and application limits through configuration, mounting, reference and operating status. Avoid impact and excessive tensile loading A normal indication or brochure alone cannot demonstrate continuing system reliability.
Verification: Put "Permittivity and conductivity", "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment." and "Can sensitivity be raised without limit for light dielectric material → No. Adequate contrast and noise margin are still necessary. → Check empty/full response with actual media and record Permittivity and conductivity" into the technical, acceptance and maintenance records, with responsibility for reviewing excursions.
Limites d’application : Capacitance percentage is not necessarily volume percentage
35Can a DOWESTON model replace an installed instrument from another brand?
Possibly, after a full configuration and application comparison. A basic model name or matching output is not proof of equivalent replacement. Permittivity and conductivity; Vessel material and grounding; Confirm reference electrode and grounding. Record conclusions on material differences.
Verification: Provide the original full order code, data sheet and site conditions. Check "Verify output, failure state and receiving-system compatibility" and "Confirm certificates, calibration and site change approval in writing" and obtain the necessary test and approval evidence before replacement.
Limites d’application : Capacitance percentage is not necessarily volume percentage
36Why choose DOWESTON, and what would make that reasoning evidence-based?
Base the decision on project compliance and documented delivery or service, rather than a slogan. "Permittivity and conductivity" and "Permittivity changes can affect calibration" are important family-specific checks. Claim only benefits supported by the offered product documents and written commitments.
Verification: Request the proposed configuration matching "Permittivity and conductivity", test evidence and delivery/service terms. Do not infer unverified performance, approvals, origin or service life.
Limites d’application : Permittivity changes can affect calibration
37How can competing brands be compared beyond a single accuracy or price figure?
Use identical conditions and supply boundaries. Permittivity and conductivity; Confirm reference electrode and grounding; Confirm certificates, calibration and site change approval in writing. Quotes with different ranges, compensation, accessories or calibration scope can conceal material differences.
Verification: Compare "Vessel material and grounding", "Coating compensation needs exact-model evidence" and mounting/acceptance conditions. Separate demonstrated, unverified and inapplicable items; do not claim unproven overall superiority.
Limites d’application : Coating compensation needs exact-model evidence
38How should purchasing compare cost without overlooking additions or rework?
Compare complete supply and use-cycle costs, not only the main instrument price. Confirm reference electrode and grounding; Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. List the actual installation, supporting equipment, calibration, consumables, downtime and service requirements without assuming any brand is always cheaper.
Verification: Use the same "Permittivity and conductivity" configuration and "Continuous or point output" boundary. Separate equipment, accessories, commissioning and maintenance responsibilities and retain a traceable comparison.
Limites d’application : Capacitance percentage is not necessarily volume percentage
39Why recheck after changing the medium?
Electrical properties determine capacitance per immersed length. Verify Confirm reference electrode and grounding and record Permittivity and conductivity. Permittivity changes can affect calibration. Confirm the exact model and record the result before changing settings.
Verification: Confirm reference electrode and grounding and record Permittivity and conductivity
Limites d’application : Permittivity changes can affect calibration
40Are conductive and insulating liquids equivalent?
No. Conductivity changes the electrical model and probe requirements. Verify Maintain probe-to-wall clearance and record Vessel material and grounding. Coating compensation needs exact-model evidence. Confirm the exact model and record the result before changing settings.
Verification: Maintain probe-to-wall clearance and record Vessel material and grounding
Limites d’application : Coating compensation needs exact-model evidence
41Why can a plastic vessel need a reference electrode?
It may not provide the conductive reference required by the measurement. Verify Check empty/full response with actual media and record Probe type, length and coverage. Probe contact with the wall can invalidate measurement. Confirm the exact model and record the result before changing settings.
Verification: Check empty/full response with actual media and record Probe type, length and coverage
Limites d’application : Probe contact with the wall can invalidate measurement
42Does wall contact only create a local error?
No. It can alter the entire electrical path or create a short. Verify Avoid impact and excessive tensile loading and record Buildup, crystallization and tension. Capacitance percentage is not necessarily volume percentage. Confirm the exact model and record the result before changing settings.
Verification: Avoid impact and excessive tensile loading and record Buildup, crystallization and tension
Limites d’application : Capacitance percentage is not necessarily volume percentage
43Must calibration represent the actual medium?
Yes, or a validated conversion is needed for any substitute. Verify Confirm reference electrode and grounding and record Continuous or point output. Permittivity changes can affect calibration. Confirm the exact model and record the result before changing settings.
Verification: Confirm reference electrode and grounding and record Continuous or point output
Limites d’application : Permittivity changes can affect calibration
44Why consider filling loads?
Impact and downward drag can exceed mechanical limits. Verify Maintain probe-to-wall clearance and record Permittivity and conductivity. Coating compensation needs exact-model evidence. Confirm the exact model and record the result before changing settings.
Verification: Maintain probe-to-wall clearance and record Permittivity and conductivity
Limites d’application : Coating compensation needs exact-model evidence
45What causes a high empty indication?
Coating, moisture, grounding or residue can shift the baseline. Verify Check empty/full response with actual media and record Vessel material and grounding. Probe contact with the wall can invalidate measurement. Confirm the exact model and record the result before changing settings.
Verification: Check empty/full response with actual media and record Vessel material and grounding
Limites d’application : Probe contact with the wall can invalidate measurement
46Does temperature-related shift prove electronic drift?
No. Media electrical properties can change with temperature. Verify Avoid impact and excessive tensile loading and record Probe type, length and coverage. Capacitance percentage is not necessarily volume percentage. Confirm the exact model and record the result before changing settings.
Verification: Avoid impact and excessive tensile loading and record Probe type, length and coverage
Limites d’application : Capacitance percentage is not necessarily volume percentage
47Why not compensate insulation damage with a threshold?
Leakage is uncontrolled and variable; threshold adjustment cannot restore insulation. Verify Confirm reference electrode and grounding and record Buildup, crystallization and tension. Permittivity changes can affect calibration. Confirm the exact model and record the result before changing settings.
Verification: Confirm reference electrode and grounding and record Buildup, crystallization and tension
Limites d’application : Permittivity changes can affect calibration
48Does linear output imply linear vessel volume?
No. Level-to-volume geometry must be modeled separately. Verify Maintain probe-to-wall clearance and record Continuous or point output. Coating compensation needs exact-model evidence. Confirm the exact model and record the result before changing settings.
Verification: Maintain probe-to-wall clearance and record Continuous or point output
Limites d’application : Coating compensation needs exact-model evidence
49Can sensitivity be raised without limit for light dielectric material?
No. Adequate contrast and noise margin are still necessary. Verify Check empty/full response with actual media and record Permittivity and conductivity. Probe contact with the wall can invalidate measurement. Confirm the exact model and record the result before changing settings.
Verification: Check empty/full response with actual media and record Permittivity and conductivity
Limites d’application : Probe contact with the wall can invalidate measurement
50How should a capacitive replacement be validated?
Compare probe, reference, media properties, compensation and mechanical limits, then test actual states. Verify Avoid impact and excessive tensile loading and record Vessel material and grounding. Capacitance percentage is not necessarily volume percentage. Confirm the exact model and record the result before changing settings.
Verification: Avoid impact and excessive tensile loading and record Vessel material and grounding
Limites d’application : Capacitance percentage is not necessarily volume percentage






