Des conditions du procédé au bon instrument
Comprenez les principes de mesure, vérifiez les conditions du procédé, configurez les produits et conservez vos ressources techniques.

The requested language edition has not been published. The complete available English version is shown below.

← Back to knowledge hub
Frequently asked questions4 min readContent language: EnglishUpdated 23 October 2026

Comparing Coriolis, magnetic, vortex and ultrasonic meters

Choose from the measurement objective and site constraints rather than treating one principle as suitable for every application.

Choose the quantity before the principle

Specify mass or volume, flow range, fluid state, allowable error and installation conditions. Each technology has advantages that depend on particular conditions; brands and models introduce further limits. This overview supports initial comparison and does not establish product suitability.

Coriolis and electromagnetic

  • Coriolis directly measures mass flow; some instruments also provide density and temperature. Check low-flow performance, pressure loss, entrained gas and wetted-material compatibility.
  • Electromagnetic measurement determines volume flow of liquids meeting the conductivity requirements. Check conductivity, full-pipe conditions, electrodes and lining materials. Diameter alone is insufficient.

Vortex and ultrasonic

  • Vortex meters use vortex-shedding frequency to determine velocity or volume flow and are used for steam, gas and liquid applications. Check low-flow limits, fluid properties, vibration and straight runs; derived mass quantities depend on the compensation configuration.
  • Ultrasonic technologies include transit-time and Doppler methods, with clamp-on and inline designs among others. Check the method, pipe material and thickness, acoustic conditions, bubbles or particles and mounting position. They cannot all be described as unaffected by the fluid.

Compare using one application worksheet

Give every candidate the same minimum, normal and maximum flow, temperature, pressure, fluid and installation information. Compare performance, maintenance, pressure loss and total cost. Treat restricted space, inability to interrupt operation and hygiene needs as explicit constraints. Keep several candidates when information is insufficient rather than forcing a single answer.

Apply this knowledge to product selection

Customers and procurement

Check actual application and acceptance requirements against the article and product documentation. Bring open questions to DOWESTON for technical review.

Sales and technical teams

Record customer questions with application conditions. Verify range, interfaces and operating requirements against the selected model documentation.

Turn questions into application requirements

Collect application, connection, installation and acceptance requirements for the selected product, then review open points with DOWESTON.

Choose a product and prepare requirements
Pas encore connecté à DOWESTON ?
Créez un compte pour commencer la sélection, consulter les prix et recevoir notre lettre d'information sur les dernières nouveautés.
Produits et services
Doweston propose une gamme de services pour vous aider à construire rapidement vos systèmes d'instrumentation automatisés. Contactez-nous pour en savoir plus.
Prêt à acheter ?
Si vous souhaitez acheter des produits,
contactez simplement notre équipe commerciale — nous serons ravis de vous aider.
Qui sommes-nous
DOWESTON fournit des solutions de mesure précises et fiables
— des produits de détection et de capteurs fiables dans tous les domaines !
Une demande de service ?
Si vous souhaitez optimiser votre production et réduire les arrêts,
nous pouvons vous aider à choisir les pièces de rechange et les services adaptés.
Modifier la configuration

Produit

Marque

Modèle

Confirmer les modifications Annuler
Votre écran est peut-être trop petit pour une navigation optimale.
Nous vous recommandons de continuer sur un ordinateur,
ou contactez immédiatement un ingénieur pour votre sélection !
Service plus rapide ? Appelez le
400-888-4436
Continuer la navigation