← Retour à la base de connaissancesNon-contact radar level measurement: 50 selection, application and maintenance questions
50 shared questions for Non-contact radar level measurement, covering selection, delivery, maintenance, common questions and evidence-based brand comparisons, with verification actions, limits and sources.
Conservez vos ressources techniques
Conservez un brouillon dans ce navigateur, puis importez-le manuellement dans votre bibliothèque après connexion.
La création de compte suit le processus habituel d’inscription et d’approbation. L’enregistrement de ressources n’ouvre pas automatiquement l’accès aux prix ni aux autres autorisations commerciales.
Shared guidance for this product family. Confirm the complete model and application; family-level guidance is not evidence of a particular product specification or approval.
Les principes généraux s’appliquent en complément de la validation du modèle. Les performances, homologations et alternatives dépendent du code de commande complet et des conditions réelles.
1What does the Non-contact radar level measurement principle establish, and what does it not establish?
Non-contact radar measures surface distance from electromagnetic echoes and converts it using the reference and vessel geometry. The principle explains signal generation; it does not establish the range, accuracy, materials or approvals of every model. Review the physical principle and the application limits separately.
Verification: Confirm "Dielectric and surface conditions" and assess "Higher frequency is not universally better" against the actual application. Record the complete model and document revision used.
Limites d’application : Higher frequency is not universally better
2Is the required result measured directly or calculated from other inputs?
Define the quantity to be accepted before selecting a display unit. Non-contact radar measures surface distance from electromagnetic echoes and converts it using the reference and vessel geometry. For "Dielectric and surface conditions", document output definitions and conversion or compensation conditions; displaying a value does not make it a direct measurement under all conditions.
Verification: Document the process objective, units and reference conditions. Check "Higher frequency is not universally better" and list separate inputs and acceptance methods for calculated results.
Limites d’application : Higher frequency is not universally better
3Which application information is needed before requesting a quotation?
Prepare at least these five input groups: Dielectric and surface conditions; Vessel, nozzle and obstructions; Band, antenna and beam; Foam, condensation and buildup; Distance range and output variable. Mark unknown items for confirmation instead of substituting a normal point or an assumed default for all conditions.
Verification: Have process, instrumentation and purchasing roles agree the inputs, particularly "Vessel, nozzle and obstructions". Resolve missing evidence before requesting application confirmation.
Limites d’application : Higher frequency is not universally better
4How should the range be chosen rather than copied from a nominal equipment rating?
Select the range from actual operating conditions and permissible error, then check extremes and installation constraints. For this family: Higher frequency is not universally better Nominal size or maximum equipment rating need not equal the useful measuring interval.
Verification: List minimum, normal, maximum and abnormal conditions. Check "Band, antenna and beam" against the documented performance envelope.
Limites d’application : Higher frequency is not universally better
5Can a larger turndown claim or display rescaling fix poor low-end performance?
No. Low-end usability depends on the principle, available signal and error mechanisms. Foam and low dielectric effects cannot be ignored More display digits, software scaling or a stated turndown cannot remove the original noise or installation error.
Verification: Obtain error definitions and limits at the actual low operating point. Use "How should agitator-related jumps be investigated → Compare echo behavior with agitation and check beam interception and splashing. → Keep obstructions and filling outside the beam and record Foam, condensation and buildup" to investigate bias instead of comparing only percent-of-full-scale values.
Limites d’application : Foam and low dielectric effects cannot be ignored
6How should compatibility with the measured object and materials be established?
Use the complete measured object and actual exposure, rather than a material name alone. Foam, condensation and buildup Avoid this family-specific misuse: Foam and low dielectric effects cannot be ignored For non-wetted equipment, assess loads, target materials, signals and environmental compatibility instead.
Verification: List the actual contact or loading parts, seals, insulation and cleaning conditions. Have the responsible parties assess "Echo mapping must not suppress the true surface".
Limites d’application : Echo mapping must not suppress the true surface
7Why must abnormal and environmental conditions be listed separately from normal operation?
Normal measurement, temporary excursions and survival limits are different requirements. Echo mapping must not suppress the true surface Start-up, cleaning, impacts, power interruption or abnormal environments can determine the necessary construction and protection.
Verification: Complete the worst-case conditions using "Distance range and output variable" and check "Distance accuracy is not inventory accuracy". Separate continuous operating limits from temporary limits in the specification.
Limites d’application : Distance accuracy is not inventory accuracy
8Can the published instrument accuracy be used as the installed system accuracy?
Not without assessment. Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. The installed system also includes object, mounting, signal conversion, environmental and reference effects. Derived results additionally depend on the relevant input uncertainties.
Verification: Agree actual test points, installation conditions and the acceptance reference. Check "Keep obstructions and filling outside the beam" and document the system error or uncertainty basis.
Limites d’application : Foam and low dielectric effects cannot be ignored
9How should response time, filtering and a stable display be balanced?
A stable indication and fast change detection involve a trade-off; filtering cannot repair incorrect installation or real process variation. Does radar measure foam or the liquid beneath it → It depends on foam properties and the instrument; validate the intended surface. → Perform mapping only with known level and record Band, antenna and beam Review the complete chain when fast response matters, not merely the display refresh rate.
Verification: Define the shortest relevant event and acceptable delay. Check "Save echo curves before parameter changes" and verify local output, display and receiving-system response using a controlled change.
Limites d’application : Echo mapping must not suppress the true surface
10Which typical applications fit, and which require a specific engineering review?
Typical contexts include: Liquid storage tank; Bulk-solids silo; Non-contact ranging in constrained vessels. Similar application labels do not establish equivalent conditions. In particular, assess "Distance accuracy is not inventory accuracy" before relying on another installation as proof.
Verification: Select the nearest application and compare "Dielectric and surface conditions" and "Distance range and output variable". Obtain written confirmation where published application limits are exceeded.
Limites d’application : Distance accuracy is not inventory accuracy
11How should a complete order code be defined without unspecified standard options?
Translate required functions, performance and physical interfaces into verifiable options. Dielectric and surface conditions; Vessel, nozzle and obstructions. Options affecting suitability or supply scope should be explicit; terms such as standard or same as existing are insufficient.
Verification: Check the complete order code and selection sheet, especially "Band, antenna and beam". List accessories, documents, calibration and delivery boundaries separately.
Limites d’application : Higher frequency is not universally better
12Which mounting and mechanical layout checks belong before ordering?
Keep obstructions and filling outside the beam The installation drawing must match the available space and process or mechanical structure. Access for fitting and servicing should be established before delivery.
Verification: Review a dimensioned, oriented site drawing. Use "Foam, condensation and buildup" and "Echo mapping must not suppress the true surface" to confirm connections, support, removal access and safe isolation.
Limites d’application : Echo mapping must not suppress the true surface
13How can supporting infrastructure prevent an instrument that fits but cannot be used?
Record antenna reference and empty/full points Supporting conditions are part of the measurement system. Matching mechanical connections or signal names alone do not establish power, I/O, grounding or configuration compatibility.
Verification: Confirm "Keep obstructions and filling outside the beam" and "Verify output, failure state and receiving-system compatibility" against actual terminals, loops and receiving-system settings.
Limites d’application : Foam and low dielectric effects cannot be ignored
14What is a sensible commissioning sequence before changing correction factors?
Check identity, installation and basic conditions first, then status, output and process response. Save echo curves before parameter changes Preserve original evidence for unexplained anomalies instead of concealing them with zero or factor adjustments.
Verification: Record factory settings and initial status. Investigate "Should zero be changed when an empty tank reads full → No. First identify the tracked echo and verify the real distance. → Save echo curves before parameter changes and record Vessel, nozzle and obstructions" step by step and change parameters only after identifying the cause and using an authorised procedure.
Limites d’application : Echo mapping must not suppress the true surface
15Do identical output units or interface names establish connection compatibility?
No. Establish the represented object and reference conditions: Dielectric and surface conditions. Electrical equipment also needs loop type, scaling, failure behaviour and protocol details checked. Mechanical indicators require clear boundaries between indication and remote-transmission accessories.
Verification: Check the receiving-system variable against "Dielectric and surface conditions" and verify limits, units and abnormal states with the actual equipment. Record wiring, configuration and end-to-end checks against "Record antenna reference and empty/full points".
Limites d’application : Foam and low dielectric effects cannot be ignored
16What should a calibration report contain to be relevant to the application?
Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. The report should identify the delivered instrument, measured quantity, conditions, method and results. A general conformity certificate does not establish performance for every option or operating condition.
Verification: Check serial number, points, units, reference equipment and traceability. Compare "Vessel, nozzle and obstructions" with the calibrated conditions and agree separate acceptance where they differ.
Limites d’application : Foam and low dielectric effects cannot be ignored
17How can delivery and site acceptance use reproducible pass criteria?
Perform mapping only with known level Agree criteria before testing, including range, conditions, error definition and treatment of anomalies. Similar-looking readings or an unsuitable portable reference are not sufficient acceptance evidence.
Verification: Choose an appropriate reference using "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment.". Record "Dielectric and surface conditions" and test conditions; investigate "How should agitator-related jumps be investigated → Compare echo behavior with agitation and check beam interception and splashing. → Keep obstructions and filling outside the beam and record Foam, condensation and buildup" before deciding on rework or recalibration.
Limites d’application : Foam and low dielectric effects cannot be ignored
18What belongs in the quotation and agreement for a non-standard application?
Define why the standard supply is insufficient, the required verification and the responsible parties. Distance accuracy is not inventory accuracy; Distance accuracy is not inventory accuracy. Additional materials, construction, documents or tests depend on actual requirements.
Verification: Attach "Distance range and output variable" and the deviations. Obtain technical confirmation, additional charges, delivery conditions and acceptance methods; unknown requirements must not be assumed satisfied.
Limites d’application : Distance accuracy is not inventory accuracy
19Where should investigation start when there is no valid reading or output?
Should zero be changed when an empty tank reads full → No. First identify the tracked echo and verify the real distance. → Save echo curves before parameter changes and record Vessel, nozzle and obstructions Distinguish the actual measured condition from device-state and readout or transmission faults. Do not immediately interpret missing data as sensor failure or a zero process value.
Verification: Under appropriate safe isolation, check "Record antenna reference and empty/full points". Compare local and receiving-end status and record when the fault appeared.
Limites d’application : Higher frequency is not universally better
20How can unstable readings be separated from genuine process variation?
Does radar measure foam or the liquid beneath it → It depends on foam properties and the instrument; validate the intended surface. → Perform mapping only with known level and record Band, antenna and beam Compare independent process evidence and raw signals before deciding whether installation, interference or equipment is responsible. More filtering can hide a real abnormal event.
Verification: Keep conditions comparable and record correlation with process or equipment events. Check "Keep obstructions and filling outside the beam" and change one factor at a time.
Limites d’application : Echo mapping must not suppress the true surface
21How should a persistent high or low bias be investigated before changing factors?
How should agitator-related jumps be investigated → Compare echo behavior with agitation and check beam interception and splashing. → Keep obstructions and filling outside the beam and record Foam, condensation and buildup Systematic bias can arise from units, reference conditions, configuration, installation or the reference method. An unexplained correction can move one operating-point error to other conditions.
Verification: Align quantities, time bases and units first. Review the reference using "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment." and confirm that "Vessel, nozzle and obstructions" matches the configuration.
Limites d’application : Foam and low dielectric effects cannot be ignored
22When is it appropriate to adjust a drifting zero or reference position?
Is increased gain enough for a coated antenna → No. Clean and inspect the antenna and compare echo profiles. → Record antenna reference and empty/full points and record Distance range and output variable Establish a genuine, stable reference condition that meets the method requirements before considering adjustment. Some instruments have no freely adjustable site zero.
Verification: Check "Save echo curves before parameter changes" and "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment." and retain before-and-after results. If the conditions cannot be established, remove external effects or use a qualified service.
Limites d’application : Echo mapping must not suppress the true surface
23Which evidence helps diagnose intermittent alarms or failures?
Does level percentage equal volume percentage → Only for suitable geometry; irregular vessels require a valid volume model. → Save echo curves before parameter changes and record Dielectric and surface conditions Intermittent faults need correlated event records, not just a normal display after recovery. Review alarm settings, communication status and actual process abnormalities separately.
Verification: Retain time, status codes, raw trends and the contemporaneous "Distance range and output variable". Compare "Record antenna reference and empty/full points" and "Save echo curves before parameter changes" to locate the failing link.
Limites d’application : Distance accuracy is not inventory accuracy
24Why should repeated failures trigger a cause review instead of another identical replacement?
Repeated failures warrant a common-cause assessment. Distance accuracy is not inventory accuracy If the external conditions remain unchanged, an identical construction or installation can experience the same failure again.
Verification: Summarise failed parts, service time and "Distance range and output variable". Check "Keep obstructions and filling outside the beam" and "Echo mapping must not suppress the true surface" and establish corrective action before selecting repair or redesign.
Limites d’application : Echo mapping must not suppress the true surface
25What distinguishes a site comparison, an adjustment and a calibration?
Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. A comparison identifies differences; adjustment changes indication or parameters; calibration establishes a reference relationship under stated conditions. They are not interchangeable claims.
Verification: Define what performance and evidence must be established, using conditions relevant to "Vessel, nozzle and obstructions". Retain original and adjusted results, references and responsibility records.
Limites d’application : Foam and low dielectric effects cannot be ignored
26What must be checked again after replacing an instrument with the same basic model?
The same basic model does not establish identical options, software, calibration or accessories. Verify output, failure state and receiving-system compatibility; Confirm certificates, calibration and site change approval in writing. Previous system operation does not remove the need to verify a replacement.
Verification: Compare full order codes and revisions. Recheck critical points, failure states and interfaces using "Perform mapping only with known level" before handover.
Limites d’application : Distance accuracy is not inventory accuracy
27Can every published maximum rating be achieved simultaneously?
No. Higher frequency is not universally better Maximum values usually relate to particular options and conditions. Temperature, load, pressure, materials, speed or signal conditions may constrain one another.
Verification: Review "Band, antenna and beam" and "Distance range and output variable" together. Obtain confirmation for the combined conditions instead of assembling unrelated maxima from separate pages.
Limites d’application : Higher frequency is not universally better
28Does a missing signal or zero indication establish that the process value is zero?
No. Should zero be changed when an empty tank reads full → No. First identify the tracked echo and verify the real distance. → Save echo curves before parameter changes and record Vessel, nozzle and obstructions Indication, measurement and transmission have distinct possible failure modes. Also consider "Higher frequency is not universally better"; establish the actual process condition independently.
Verification: Check available status or failure indications and "Keep obstructions and filling outside the beam". For interlocks, follow the complete safety design rather than substituting a zero value for diagnosis.
Limites d’application : Higher frequency is not universally better
29Does one acceptable test point establish compliance across the working range?
No. Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. Test points and directions must reflect the working interval, relevant error mechanisms and acceptance purpose. Multiple points, reversal or load tests depend on the method.
Verification: Define acceptance coverage against "Vessel, nozzle and obstructions" and include critical operating points. Mark conditions outside the tests as unverified.
Limites d’application : Foam and low dielectric effects cannot be ignored
30Are the largest range, highest accuracy class and most options always preferable?
Not necessarily. Options should serve the required objective; excess configuration can add cost, complexity or incompatibility. Foam and low dielectric effects cannot be ignored; Foam and low dielectric effects cannot be ignored. Establish essential requirements before comparing optional benefits.
Verification: Document the objective in "Dielectric and surface conditions" and why "Dielectric and surface conditions" is needed. Compare performance at actual working points rather than one headline metric.
Limites d’application : Foam and low dielectric effects cannot be ignored
31Can every maintenance or recalibration interval simply be fixed at one year?
Not independently of risk and history. Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. Intervals depend on applicable law or contract, conditions, drift, maintenance and failure evidence. Generic advice cannot replace mandatory requirements.
Verification: Use "Is increased gain enough for a coated antenna → No. Clean and inspect the antenna and compare echo profiles. → Record antenna reference and empty/full points and record Distance range and output variable" and "Distance accuracy is not inventory accuracy" to establish and review an initial plan. Retain the justification and approval for interval changes.
Limites d’application : Distance accuracy is not inventory accuracy
32Can parts from different brands be mixed if their physical interfaces fit?
Physical fit is insufficient. Vessel, nozzle and obstructions; Keep obstructions and filling outside the beam. Matching, materials, signals, calibration and approval boundaries can change with the combination.
Verification: Check the complete combination against "Record antenna reference and empty/full points" and obtain compatibility and acceptance evidence. An unconfirmed assembly must not be described as an approved system.
Limites d’application : Foam and low dielectric effects cannot be ignored
33Does a hazardous-area, hygienic or safety label establish suitability for that duty?
Check the exact order configuration and valid documents rather than a series name. Confirm certificates, calibration and site change approval in writing "Distance accuracy is not inventory accuracy" also matters; certificates, installation conditions and restrictions together define suitability.
Verification: Obtain certificate identifiers, covered models and special conditions and match them to the site. Similar names do not grant functional-safety or legal-metrology approval.
Limites d’application : Distance accuracy is not inventory accuracy
34What evidence makes the final result acceptable, reproducible and sustainable?
Establish the chain from quantity definition and application limits through configuration, mounting, reference and operating status. Perform mapping only with known level A normal indication or brochure alone cannot demonstrate continuing system reliability.
Verification: Put "Dielectric and surface conditions", "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment." and "Does level percentage equal volume percentage → Only for suitable geometry; irregular vessels require a valid volume model. → Save echo curves before parameter changes and record Dielectric and surface conditions" into the technical, acceptance and maintenance records, with responsibility for reviewing excursions.
Limites d’application : Distance accuracy is not inventory accuracy
35Can a DOWESTON model replace an installed instrument from another brand?
Possibly, after a full configuration and application comparison. A basic model name or matching output is not proof of equivalent replacement. Dielectric and surface conditions; Vessel, nozzle and obstructions; Keep obstructions and filling outside the beam. Record conclusions on material differences.
Verification: Provide the original full order code, data sheet and site conditions. Check "Verify output, failure state and receiving-system compatibility" and "Confirm certificates, calibration and site change approval in writing" and obtain the necessary test and approval evidence before replacement.
Limites d’application : Distance accuracy is not inventory accuracy
36Why choose DOWESTON, and what would make that reasoning evidence-based?
Base the decision on project compliance and documented delivery or service, rather than a slogan. "Dielectric and surface conditions" and "Higher frequency is not universally better" are important family-specific checks. Claim only benefits supported by the offered product documents and written commitments.
Verification: Request the proposed configuration matching "Dielectric and surface conditions", test evidence and delivery/service terms. Do not infer unverified performance, approvals, origin or service life.
Limites d’application : Higher frequency is not universally better
37How can competing brands be compared beyond a single accuracy or price figure?
Use identical conditions and supply boundaries. Dielectric and surface conditions; Keep obstructions and filling outside the beam; Confirm certificates, calibration and site change approval in writing. Quotes with different ranges, compensation, accessories or calibration scope can conceal material differences.
Verification: Compare "Vessel, nozzle and obstructions", "Foam and low dielectric effects cannot be ignored" and mounting/acceptance conditions. Separate demonstrated, unverified and inapplicable items; do not claim unproven overall superiority.
Limites d’application : Foam and low dielectric effects cannot be ignored
38How should purchasing compare cost without overlooking additions or rework?
Compare complete supply and use-cycle costs, not only the main instrument price. Keep obstructions and filling outside the beam; Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. List the actual installation, supporting equipment, calibration, consumables, downtime and service requirements without assuming any brand is always cheaper.
Verification: Use the same "Dielectric and surface conditions" configuration and "Distance range and output variable" boundary. Separate equipment, accessories, commissioning and maintenance responsibilities and retain a traceable comparison.
Limites d’application : Distance accuracy is not inventory accuracy
39Is 80GHz always superior?
A narrower beam can help, but antenna and process conditions still determine suitability. Verify Keep obstructions and filling outside the beam and record Dielectric and surface conditions. Higher frequency is not universally better. Confirm the exact model and record the result before changing settings.
Verification: Keep obstructions and filling outside the beam and record Dielectric and surface conditions
Limites d’application : Higher frequency is not universally better
40Does non-contact mean compatibility is irrelevant?
No. Antennas and seals may contact vapor, condensate and cleaning media. Verify Record antenna reference and empty/full points and record Vessel, nozzle and obstructions. Foam and low dielectric effects cannot be ignored. Confirm the exact model and record the result before changing settings.
Verification: Record antenna reference and empty/full points and record Vessel, nozzle and obstructions
Limites d’application : Foam and low dielectric effects cannot be ignored
41Why can low-dielectric liquids be difficult?
Weak surface reflections can be outweighed by bottom or obstruction echoes. Verify Save echo curves before parameter changes and record Band, antenna and beam. Echo mapping must not suppress the true surface. Confirm the exact model and record the result before changing settings.
Verification: Save echo curves before parameter changes and record Band, antenna and beam
Limites d’application : Echo mapping must not suppress the true surface
42Can mapping be performed blindly at any level?
No. The true surface must be known to avoid suppressing its echo. Verify Perform mapping only with known level and record Foam, condensation and buildup. Distance accuracy is not inventory accuracy. Confirm the exact model and record the result before changing settings.
Verification: Perform mapping only with known level and record Foam, condensation and buildup
Limites d’application : Distance accuracy is not inventory accuracy
43Why can a nozzle affect radar?
Nozzle reflections, antenna position and condensate affect near-field echoes. Verify Keep obstructions and filling outside the beam and record Distance range and output variable. Higher frequency is not universally better. Confirm the exact model and record the result before changing settings.
Verification: Keep obstructions and filling outside the beam and record Distance range and output variable
Limites d’application : Higher frequency is not universally better
44Why must the reference plane be consistent?
Using an assumed reference introduces a fixed distance offset. Verify Record antenna reference and empty/full points and record Dielectric and surface conditions. Foam and low dielectric effects cannot be ignored. Confirm the exact model and record the result before changing settings.
Verification: Record antenna reference and empty/full points and record Dielectric and surface conditions
Limites d’application : Foam and low dielectric effects cannot be ignored
45Should zero be changed when an empty tank reads full?
No. First identify the tracked echo and verify the real distance. Verify Save echo curves before parameter changes and record Vessel, nozzle and obstructions. Echo mapping must not suppress the true surface. Confirm the exact model and record the result before changing settings.
Verification: Save echo curves before parameter changes and record Vessel, nozzle and obstructions
Limites d’application : Echo mapping must not suppress the true surface
46Does radar measure foam or the liquid beneath it?
It depends on foam properties and the instrument; validate the intended surface. Verify Perform mapping only with known level and record Band, antenna and beam. Distance accuracy is not inventory accuracy. Confirm the exact model and record the result before changing settings.
Verification: Perform mapping only with known level and record Band, antenna and beam
Limites d’application : Distance accuracy is not inventory accuracy
47How should agitator-related jumps be investigated?
Compare echo behavior with agitation and check beam interception and splashing. Verify Keep obstructions and filling outside the beam and record Foam, condensation and buildup. Higher frequency is not universally better. Confirm the exact model and record the result before changing settings.
Verification: Keep obstructions and filling outside the beam and record Foam, condensation and buildup
Limites d’application : Higher frequency is not universally better
48Is increased gain enough for a coated antenna?
No. Clean and inspect the antenna and compare echo profiles. Verify Record antenna reference and empty/full points and record Distance range and output variable. Foam and low dielectric effects cannot be ignored. Confirm the exact model and record the result before changing settings.
Verification: Record antenna reference and empty/full points and record Distance range and output variable
Limites d’application : Foam and low dielectric effects cannot be ignored
49Does level percentage equal volume percentage?
Only for suitable geometry; irregular vessels require a valid volume model. Verify Save echo curves before parameter changes and record Dielectric and surface conditions. Echo mapping must not suppress the true surface. Confirm the exact model and record the result before changing settings.
Verification: Save echo curves before parameter changes and record Dielectric and surface conditions
Limites d’application : Echo mapping must not suppress the true surface
50Why retain old echo curves for replacement?
They document actual surface and obstruction signals for application comparison. Verify Perform mapping only with known level and record Vessel, nozzle and obstructions. Distance accuracy is not inventory accuracy. Confirm the exact model and record the result before changing settings.
Verification: Perform mapping only with known level and record Vessel, nozzle and obstructions
Limites d’application : Distance accuracy is not inventory accuracy