Des conditions du procédé au bon instrument
Comprenez les principes de mesure, vérifiez les conditions du procédé, configurez les produits et conservez vos ressources techniques.

La version française n’est pas encore disponible. La version complète en anglais est présentée ci-dessous.

← Retour à la base de connaissances
Sélection et applications3 min de lectureLangue du contenu: anglaisMis à jour 23 octobre 2026

Electromagnetic flowmeters: why must the measuring tube stay full?

A conventional full-bore electromagnetic flowmeter calculates flow using the complete cross-sectional area of the tube. A partly filled tube invalidates that assumption and can disrupt measurement.

Check pipe fill before changing the meter settings

A conventional full-bore electromagnetic flowmeter calculates flow using the complete cross-sectional area of the tube. A partly filled tube invalidates that assumption and can disrupt measurement.

Partial fill changes the wetted area and may interrupt electrode contact. Check how to maintain a full tube before changing the configured pipe diameter.

Evaluate the full operating cycle

The tube must remain full throughout the operating cycle, including startup and shutdown. Gas can collect at high points, a free discharge can lower the liquid level, and the pipe can drain after the pump stops. Check the installation elevations and pressure conditions. The absence of an alarm is not proof that the tube is always full and free of gas.

Identify high points and drain paths. When comparing replacement meters, check mechanical and electrical connections, functions and calibration compatibility. Similar appearance or connections are only part of the comparison. Verify software options and accessories against the actual delivery. Record the complete model code, drawings and checks once the configuration is fixed. After service, verify which original installation conditions the replacement changed.

Field checks

  • Identify the highest points and drain paths. Record flow readings and any electrode or empty-pipe diagnostics available from the instrument. Flag readings you collected and diagnostic functions the meter actually supports.
  • List the minimum, typical and most unfavorable fill conditions. Record how long each lasts and where the data came from.
  • Select a reference suited to the instrument and process. Record the original configuration and operating conditions before the comparison. Change one factor at a time based on the observed evidence.

Example: gravity drainage and pump restart

Suppose a gravity drain carries water only in the bottom half of the pipe. If the crown is exposed to air after the pump stops and the tube fills only some time after restart, mark which data are valid before and after the transition.

Compare the current conditions with the conditions used to select the meter.

Document what was verified

Support the conclusion about tube fill with observations of high points and drain paths. Record the operating states covered, the comparison basis and any open items. Retain the observations and original setup. Simulation at the output verifies only the portion of the measurement chain that was tested.

This is an illustrative case. Follow the limits of the installed model and the site procedures. Use Doweston’s supply documents to confirm equipment specifications and certification.

Appliquez ces connaissances à la sélection

Clients et achats

Vérifiez les conditions réelles et les critères de réception dans l’article et la documentation du produit. Soumettez les points ouverts au service technique DOWESTON.

Équipes commerciales et techniques

Notez les questions du client et ses conditions de service. Vérifiez la plage, les raccordements et les conditions d’utilisation dans la documentation du modèle sélectionné.

Transformez les questions en critères de sélection

Relevez le fluide, les raccordements, le montage et les critères de réception du produit, puis examinez les points ouverts avec DOWESTON.

Choisir un produit et préparer les conditions de service
Pas encore connecté à DOWESTON ?
Créez un compte pour commencer la sélection, consulter les prix et recevoir notre lettre d'information sur les dernières nouveautés.
Produits et services
Doweston propose une gamme de services pour vous aider à construire rapidement vos systèmes d'instrumentation automatisés. Contactez-nous pour en savoir plus.
Prêt à acheter ?
Si vous souhaitez acheter des produits,
contactez simplement notre équipe commerciale — nous serons ravis de vous aider.
Qui sommes-nous
DOWESTON fournit des solutions de mesure précises et fiables
— des produits de détection et de capteurs fiables dans tous les domaines !
Une demande de service ?
Si vous souhaitez optimiser votre production et réduire les arrêts,
nous pouvons vous aider à choisir les pièces de rechange et les services adaptés.
Modifier la configuration

Nom du produit

Marque

Modèle

Confirmer les modifications Annuler
Votre écran est peut-être trop petit pour une navigation optimale.
Nous vous recommandons de continuer sur un ordinateur,
ou contactez immédiatement un ingénieur pour votre sélection !
Service plus rapide ? Appelez le
400-888-4436
Continuer la navigation