Des conditions du procédé au bon instrument
Comprenez les principes de mesure, vérifiez les conditions du procédé, configurez les produits et conservez vos ressources techniques.

La version française n’est pas encore disponible. La version complète en anglais est présentée ci-dessous.

← Retour à la base de connaissances
Principes de mesure5 min de lectureLangue du contenu: anglaisMis à jour 23 octobre 2026

Pressure sensors, sensing elements and pressure transmitters: how do you tell them apart when buying?

Before ordering, confirm whether the supplier is delivering a complete device ready to wire or a sensing element that needs further design work.

Start with the scope of supply

A pressure sensor converts pressure into an electrical signal. Suppliers do not use the terms sensor and transmitter consistently. A product sold as a pressure sensor may offer only a millivolt bridge output, or it may already include amplification, compensation, protection circuitry and an industrial connector. Similar names can conceal very different installation and signal acquisition requirements.

Check the interfaces for compatibility

When connecting to existing equipment, check the output type, supply voltage range, wiring arrangement, pressure connection and electrical connection. Do not connect a bare sensing element intended for development directly to a PLC analog input. Similar housings do not establish that two complete devices are interchangeable. Confirm separately any required local display, switching or communications functions.

Put your requirements in a supply checklist

Send Doweston the process medium, pressure range, receiving equipment input type, available power supply and photographs of the connections. Specify whether the request is for a complete replacement or for OEM development. When confirming a quotation, list whether the plug, cable, seals and calibration documents are included so procurement, installation and commissioning teams agree on the scope of supply.

On-site check: identify the level of integration you are buying

  • State whether the supplier will deliver a bare sensing element, a module with circuitry or a complete packaged device. Include the full model and version rather than just the generic name.
  • Check whether the output is already amplified and temperature-compensated. Confirm that its signal and terminals match the receiving equipment.
  • Assign responsibility for the pressure connection, electrical plug and signal interface circuitry separately. List what the customer needs to design or purchase.
  • Agree who will calibrate the complete device, test sealing and commission the system. Specify whether the report covers the device itself or the entire measurement chain.

Example: two quotations use the same name but deliver different products

Suppose a customer receives two quotations both labeled pressure sensor. One covers a bare element with a bridge output. The other covers a complete device with an industrial output and connector. The price of the first item is lower, but it leaves the customer to provide excitation, amplification, compensation, sealing and calibration. Comparing item prices alone will not show the system cost. Put that work and the cost of development and validation on the same checklist.

Sales should ask what originally acquired the signal, whether the supporting circuitry already exists and whether this is a production development project or a maintenance replacement. If the customer is replacing a failed part during downtime, a compatible complete device and clear wiring instructions may be more important. If the customer has development capability, discuss what the module needs to include. This is an illustrative case, not a statement about the scope of supply of any current Doweston model.

Appliquez ces connaissances à la sélection

Clients et achats

Vérifiez les conditions réelles et les critères de réception dans l’article et la documentation du produit. Soumettez les points ouverts au service technique DOWESTON.

Équipes commerciales et techniques

Notez les questions du client et ses conditions de service. Vérifiez la plage, les raccordements et les conditions d’utilisation dans la documentation du modèle sélectionné.

Transformez les questions en critères de sélection

Relevez le fluide, les raccordements, le montage et les critères de réception du produit, puis examinez les points ouverts avec DOWESTON.

Choisir un produit et préparer les conditions de service
Pas encore connecté à DOWESTON ?
Créez un compte pour commencer la sélection, consulter les prix et recevoir notre lettre d'information sur les dernières nouveautés.
Produits et services
Doweston propose une gamme de services pour vous aider à construire rapidement vos systèmes d'instrumentation automatisés. Contactez-nous pour en savoir plus.
Prêt à acheter ?
Si vous souhaitez acheter des produits,
contactez simplement notre équipe commerciale — nous serons ravis de vous aider.
Qui sommes-nous
DOWESTON fournit des solutions de mesure précises et fiables
— des produits de détection et de capteurs fiables dans tous les domaines !
Une demande de service ?
Si vous souhaitez optimiser votre production et réduire les arrêts,
nous pouvons vous aider à choisir les pièces de rechange et les services adaptés.
Modifier la configuration

Nom du produit

Marque

Modèle

Confirmer les modifications Annuler
Votre écran est peut-être trop petit pour une navigation optimale.
Nous vous recommandons de continuer sur un ordinateur,
ou contactez immédiatement un ingénieur pour votre sélection !
Service plus rapide ? Appelez le
400-888-4436
Continuer la navigation