La version française n’est pas encore disponible. La version complète en anglais est présentée ci-dessous.
← Retour à la base de connaissancesMagnetostrictive position transducers: 50 selection, application and maintenance questions
50 shared questions for Magnetostrictive position transducers, covering selection, delivery, maintenance, common questions and evidence-based brand comparisons, with verification actions, limits and sources.
Conservez vos ressources techniques
Conservez un brouillon dans ce navigateur, puis importez-le manuellement dans votre bibliothèque après connexion.
La création de compte suit le processus habituel d’inscription et d’approbation. L’enregistrement de ressources n’ouvre pas automatiquement l’accès aux prix ni aux autres autorisations commerciales.
Shared guidance for this product family. Confirm the complete model and application; family-level guidance is not evidence of a particular product specification or approval.
Les principes généraux s’appliquent en complément de la validation du modèle. Les performances, homologations et alternatives dépendent du code de commande complet et des conditions réelles.
1What does the Magnetostrictive position transducers principle establish, and what does it not establish?
A magnetostrictive position sensor determines position from the travel time of a torsional wave generated by an electrical pulse interacting with a position magnet. The sensing principle is non-contact, but mechanical assemblies retain installation and load limits. The principle explains signal generation; it does not establish the range, accuracy, materials or approvals of every model. Review the physical principle and the application limits separately.
Verification: Confirm "Active stroke, zero direction and space at both ends" and assess "Overall mechanical length is not active stroke; end dead zones matter" against the actual application. Record the complete model and document revision used.
Limites d’application : Overall mechanical length is not active stroke; end dead zones matter
2Is the required result measured directly or calculated from other inputs?
Define the quantity to be accepted before selecting a display unit. A magnetostrictive position sensor determines position from the travel time of a torsional wave generated by an electrical pulse interacting with a position magnet. The sensing principle is non-contact, but mechanical assemblies retain installation and load limits. For "Active stroke, zero direction and space at both ends", document output definitions and conversion or compensation conditions; displaying a value does not make it a direct measurement under all conditions.
Verification: Document the process objective, units and reference conditions. Check "Treating overall length as active stroke" and list separate inputs and acceptance methods for calculated results.
Limites d’application : Treating overall length as active stroke
3Which application information is needed before requesting a quotation?
Prepare at least these five input groups: Active stroke, zero direction and space at both ends; Magnet type, count, orientation and spacing; Rod, slider or jointed construction and mechanical connection; Motion speed, update period, output and control interface; Pressure construction, temperature, vibration and environment. Mark unknown items for confirmation instead of substituting a normal point or an assumed default for all conditions.
Verification: Have process, instrumentation and purchasing roles agree the inputs, particularly "Magnet type, count, orientation and spacing". Resolve missing evidence before requesting application confirmation.
Limites d’application : Overall mechanical length is not active stroke; end dead zones matter
4How should the range be chosen rather than copied from a nominal equipment rating?
Select the range from actual operating conditions and permissible error, then check extremes and installation constraints. For this family: Overall mechanical length is not active stroke; end dead zones matter Nominal size or maximum equipment rating need not equal the useful measuring interval.
Verification: List minimum, normal, maximum and abnormal conditions. Check "Rod, slider or jointed construction and mechanical connection" against the documented performance envelope.
Limites d’application : Overall mechanical length is not active stroke; end dead zones matter
5Can a larger turndown claim or display rescaling fix poor low-end performance?
No. Low-end usability depends on the principle, available signal and error mechanisms. Magnet, spacing and nearby ferromagnetic material affect detection More display digits, software scaling or a stated turndown cannot remove the original noise or installation error.
Verification: Obtain error definitions and limits at the actual low operating point. Use "Scale/direction error: inspect stroke, scaling and code interpretation" to investigate bias instead of comparing only percent-of-full-scale values.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
6How should compatibility with the measured object and materials be established?
Use the complete measured object and actual exposure, rather than a material name alone. Motion speed, update period, output and control interface Avoid this family-specific misuse: Replacing the specified magnet with an arbitrary magnet or steel part For non-wetted equipment, assess loads, target materials, signals and environmental compatibility instead.
Verification: List the actual contact or loading parts, seals, insulation and cleaning conditions. Have the responsible parties assess "Absolute position still needs zero, direction and controller-coordinate checks".
Limites d’application : Absolute position still needs zero, direction and controller-coordinate checks
7Why must abnormal and environmental conditions be listed separately from normal operation?
Normal measurement, temporary excursions and survival limits are different requirements. Absolute position still needs zero, direction and controller-coordinate checks Start-up, cleaning, impacts, power interruption or abnormal environments can determine the necessary construction and protection.
Verification: Complete the worst-case conditions using "Pressure construction, temperature, vibration and environment" and check "Pressure rating applies only to the specified structure and boundary". Separate continuous operating limits from temporary limits in the specification.
Limites d’application : Pressure rating applies only to the specified structure and boundary
8Can the published instrument accuracy be used as the installed system accuracy?
Not without assessment. Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy. The installed system also includes object, mounting, signal conversion, environmental and reference effects. Derived results additionally depend on the relevant input uncertainties.
Verification: Agree actual test points, installation conditions and the acceptance reference. Check "Arrange magnet motion within the active stroke/dead zones and avoid impact" and document the system error or uncertainty basis.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
9How should response time, filtering and a stable display be balanced?
A stable indication and fast change detection involve a trade-off; filtering cannot repair incorrect installation or real process variation. Position jumps: inspect magnet motion/spacing, interference and communication Review the complete chain when fast response matters, not merely the display refresh rate.
Verification: Define the shortest relevant event and acceptable delay. Check "Match protocol, supply and scaling and verify direction" and verify local output, display and receiving-system response using a controlled change.
Limites d’application : Assuming a matching SSI-type connector proves protocol compatibility
10Which typical applications fit, and which require a specific engineering review?
Typical contexts include: Hydraulic-cylinder position feedback; Linear machine-stroke monitoring; Slider or jointed-rod position control. Similar application labels do not establish equivalent conditions. In particular, assess "Pressure rating applies only to the specified structure and boundary" before relying on another installation as proof.
Verification: Select the nearest application and compare "Active stroke, zero direction and space at both ends" and "Pressure construction, temperature, vibration and environment". Obtain written confirmation where published application limits are exceeded.
Limites d’application : Pressure rating applies only to the specified structure and boundary
11How should a complete order code be defined without unspecified standard options?
Translate required functions, performance and physical interfaces into verifiable options. Mechanical form, active stroke, dead zones and zero direction; Magnet matching, clearances and linkage geometry. Options affecting suitability or supply scope should be explicit; terms such as standard or same as existing are insufficient.
Verification: Check the complete order code and selection sheet, especially "Rod, slider or jointed construction and mechanical connection". List accessories, documents, calibration and delivery boundaries separately.
Limites d’application : Treating overall length as active stroke
12Which mounting and mechanical layout checks belong before ordering?
Arrange magnet motion within the active stroke/dead zones and avoid impact The installation drawing must match the available space and process or mechanical structure. Access for fitting and servicing should be established before delivery.
Verification: Review a dimensioned, oriented site drawing. Use "Motion speed, update period, output and control interface" and "Absolute position still needs zero, direction and controller-coordinate checks" to confirm connections, support, removal access and safe isolation.
Limites d’application : Absolute position still needs zero, direction and controller-coordinate checks
13How can supporting infrastructure prevent an instrument that fits but cannot be used?
Use approved magnets and specified spacers and clearances Supporting conditions are part of the measurement system. Matching mechanical connections or signal names alone do not establish power, I/O, grounding or configuration compatibility.
Verification: Confirm "Power, protocol, resolution and update period" and "Pressure boundary, temperature, vibration and cable" against actual terminals, loops and receiving-system settings.
Limites d’application : Replacing the specified magnet with an arbitrary magnet or steel part
14What is a sensible commissioning sequence before changing correction factors?
Check identity, installation and basic conditions first, then status, output and process response. Match protocol, supply and scaling and verify direction Preserve original evidence for unexplained anomalies instead of concealing them with zero or factor adjustments.
Verification: Record factory settings and initial status. Investigate "No position: inspect magnet presence, orientation, spacing and electrical state" step by step and change parameters only after identifying the cause and using an authorised procedure.
Limites d’application : Assuming a matching SSI-type connector proves protocol compatibility
15Do identical output units or interface names establish connection compatibility?
No. Establish the represented object and reference conditions: Mechanical form, active stroke, dead zones and zero direction. Electrical equipment also needs loop type, scaling, failure behaviour and protocol details checked. Mechanical indicators require clear boundaries between indication and remote-transmission accessories.
Verification: Check the receiving-system variable against "Active stroke, zero direction and space at both ends" and verify limits, units and abnormal states with the actual equipment. Record wiring, configuration and end-to-end checks against "Use approved magnets and specified spacers and clearances".
Limites d’application : Replacing the specified magnet with an arbitrary magnet or steel part
16What should a calibration report contain to be relevant to the application?
Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy. The report should identify the delivered instrument, measured quantity, conditions, method and results. A general conformity certificate does not establish performance for every option or operating condition.
Verification: Check serial number, points, units, reference equipment and traceability. Compare "Magnet type, count, orientation and spacing" with the calibrated conditions and agree separate acceptance where they differ.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
17How can delivery and site acceptance use reproducible pass criteria?
Verify known positions at both ends/middle and test motion and faults separately Agree criteria before testing, including range, conditions, error definition and treatment of anomalies. Similar-looking readings or an unsuitable portable reference are not sufficient acceptance evidence.
Verification: Choose an appropriate reference using "Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy.". Record "Active stroke, zero direction and space at both ends" and test conditions; investigate "Scale/direction error: inspect stroke, scaling and code interpretation" before deciding on rework or recalibration.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
18What belongs in the quotation and agreement for a non-standard application?
Define why the standard supply is insufficient, the required verification and the responsible parties. Pressure rating applies only to the specified structure and boundary; Treating non-contact sensing as proof that mechanical joints never wear. Additional materials, construction, documents or tests depend on actual requirements.
Verification: Attach "Pressure construction, temperature, vibration and environment" and the deviations. Obtain technical confirmation, additional charges, delivery conditions and acceptance methods; unknown requirements must not be assumed satisfied.
Limites d’application : Pressure rating applies only to the specified structure and boundary
19Where should investigation start when there is no valid reading or output?
No position: inspect magnet presence, orientation, spacing and electrical state Distinguish the actual measured condition from device-state and readout or transmission faults. Do not immediately interpret missing data as sensor failure or a zero process value.
Verification: Under appropriate safe isolation, check "Use approved magnets and specified spacers and clearances". Compare local and receiving-end status and record when the fault appeared.
Limites d’application : Treating overall length as active stroke
20How can unstable readings be separated from genuine process variation?
Position jumps: inspect magnet motion/spacing, interference and communication Compare independent process evidence and raw signals before deciding whether installation, interference or equipment is responsible. More filtering can hide a real abnormal event.
Verification: Keep conditions comparable and record correlation with process or equipment events. Check "Arrange magnet motion within the active stroke/dead zones and avoid impact" and change one factor at a time.
Limites d’application : Assuming a matching SSI-type connector proves protocol compatibility
21How should a persistent high or low bias be investigated before changing factors?
Scale/direction error: inspect stroke, scaling and code interpretation Systematic bias can arise from units, reference conditions, configuration, installation or the reference method. An unexplained correction can move one operating-point error to other conditions.
Verification: Align quantities, time bases and units first. Review the reference using "Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy." and confirm that "Magnet type, count, orientation and spacing" matches the configuration.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
22When is it appropriate to adjust a drifting zero or reference position?
End anomalies: inspect dead zones, collision and overtravel Establish a genuine, stable reference condition that meets the method requirements before considering adjustment. Some instruments have no freely adjustable site zero.
Verification: Check "Match protocol, supply and scaling and verify direction" and "Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy." and retain before-and-after results. If the conditions cannot be established, remove external effects or use a qualified service.
Limites d’application : Assuming a matching SSI-type connector proves protocol compatibility
23Which evidence helps diagnose intermittent alarms or failures?
Temperature-related shift: inspect structural expansion, magnet linkage and sensor temperature behaviour Intermittent faults need correlated event records, not just a normal display after recovery. Review alarm settings, communication status and actual process abnormalities separately.
Verification: Retain time, status codes, raw trends and the contemporaneous "Pressure construction, temperature, vibration and environment". Compare "Use approved magnets and specified spacers and clearances" and "Match protocol, supply and scaling and verify direction" to locate the failing link.
Limites d’application : Treating non-contact sensing as proof that mechanical joints never wear
24Why should repeated failures trigger a cause review instead of another identical replacement?
Repeated failures warrant a common-cause assessment. Treating non-contact sensing as proof that mechanical joints never wear If the external conditions remain unchanged, an identical construction or installation can experience the same failure again.
Verification: Summarise failed parts, service time and "Pressure construction, temperature, vibration and environment". Check "Arrange magnet motion within the active stroke/dead zones and avoid impact" and "Absolute position still needs zero, direction and controller-coordinate checks" and establish corrective action before selecting repair or redesign.
Limites d’application : Absolute position still needs zero, direction and controller-coordinate checks
25What distinguishes a site comparison, an adjustment and a calibration?
Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy. A comparison identifies differences; adjustment changes indication or parameters; calibration establishes a reference relationship under stated conditions. They are not interchangeable claims.
Verification: Define what performance and evidence must be established, using conditions relevant to "Magnet type, count, orientation and spacing". Retain original and adjusted results, references and responsibility records.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
26What must be checked again after replacing an instrument with the same basic model?
The same basic model does not establish identical options, software, calibration or accessories. Pressure boundary, temperature, vibration and cable; Order-specific calibration, hazardous-area and safety-duty documents. Previous system operation does not remove the need to verify a replacement.
Verification: Compare full order codes and revisions. Recheck critical points, failure states and interfaces using "Verify known positions at both ends/middle and test motion and faults separately" before handover.
Limites d’application : Treating non-contact sensing as proof that mechanical joints never wear
27Can every published maximum rating be achieved simultaneously?
No. Overall mechanical length is not active stroke; end dead zones matter Maximum values usually relate to particular options and conditions. Temperature, load, pressure, materials, speed or signal conditions may constrain one another.
Verification: Review "Rod, slider or jointed construction and mechanical connection" and "Pressure construction, temperature, vibration and environment" together. Obtain confirmation for the combined conditions instead of assembling unrelated maxima from separate pages.
Limites d’application : Overall mechanical length is not active stroke; end dead zones matter
28Does a missing signal or zero indication establish that the process value is zero?
No. No position: inspect magnet presence, orientation, spacing and electrical state Indication, measurement and transmission have distinct possible failure modes. Also consider "Treating overall length as active stroke"; establish the actual process condition independently.
Verification: Check available status or failure indications and "Power, protocol, resolution and update period". For interlocks, follow the complete safety design rather than substituting a zero value for diagnosis.
Limites d’application : Treating overall length as active stroke
29Does one acceptable test point establish compliance across the working range?
No. Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy. Test points and directions must reflect the working interval, relevant error mechanisms and acceptance purpose. Multiple points, reversal or load tests depend on the method.
Verification: Define acceptance coverage against "Magnet type, count, orientation and spacing" and include critical operating points. Mark conditions outside the tests as unverified.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
30Are the largest range, highest accuracy class and most options always preferable?
Not necessarily. Options should serve the required objective; excess configuration can add cost, complexity or incompatibility. Magnet, spacing and nearby ferromagnetic material affect detection; Replacing the specified magnet with an arbitrary magnet or steel part. Establish essential requirements before comparing optional benefits.
Verification: Document the objective in "Active stroke, zero direction and space at both ends" and why "Mechanical form, active stroke, dead zones and zero direction" is needed. Compare performance at actual working points rather than one headline metric.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
31Can every maintenance or recalibration interval simply be fixed at one year?
Not independently of risk and history. Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy. Intervals depend on applicable law or contract, conditions, drift, maintenance and failure evidence. Generic advice cannot replace mandatory requirements.
Verification: Use "End anomalies: inspect dead zones, collision and overtravel" and "Treating non-contact sensing as proof that mechanical joints never wear" to establish and review an initial plan. Retain the justification and approval for interval changes.
Limites d’application : Treating non-contact sensing as proof that mechanical joints never wear
32Can parts from different brands be mixed if their physical interfaces fit?
Physical fit is insufficient. Magnet matching, clearances and linkage geometry; Power, protocol, resolution and update period. Matching, materials, signals, calibration and approval boundaries can change with the combination.
Verification: Check the complete combination against "Use approved magnets and specified spacers and clearances" and obtain compatibility and acceptance evidence. An unconfirmed assembly must not be described as an approved system.
Limites d’application : Replacing the specified magnet with an arbitrary magnet or steel part
33Does a hazardous-area, hygienic or safety label establish suitability for that duty?
Check the exact order configuration and valid documents rather than a series name. Order-specific calibration, hazardous-area and safety-duty documents "Pressure rating applies only to the specified structure and boundary" also matters; certificates, installation conditions and restrictions together define suitability.
Verification: Obtain certificate identifiers, covered models and special conditions and match them to the site. Similar names do not grant functional-safety or legal-metrology approval.
Limites d’application : Pressure rating applies only to the specified structure and boundary
34What evidence makes the final result acceptable, reproducible and sustainable?
Establish the chain from quantity definition and application limits through configuration, mounting, reference and operating status. Verify known positions at both ends/middle and test motion and faults separately A normal indication or brochure alone cannot demonstrate continuing system reliability.
Verification: Put "Active stroke, zero direction and space at both ends", "Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy." and "Temperature-related shift: inspect structural expansion, magnet linkage and sensor temperature behaviour" into the technical, acceptance and maintenance records, with responsibility for reviewing excursions.
Limites d’application : Pressure rating applies only to the specified structure and boundary
35Can a DOWESTON model replace an installed instrument from another brand?
Possibly, after a full configuration and application comparison. A basic model name or matching output is not proof of equivalent replacement. Mechanical form, active stroke, dead zones and zero direction; Magnet matching, clearances and linkage geometry; Power, protocol, resolution and update period. Record conclusions on material differences.
Verification: Provide the original full order code, data sheet and site conditions. Check "Pressure boundary, temperature, vibration and cable" and "Order-specific calibration, hazardous-area and safety-duty documents" and obtain the necessary test and approval evidence before replacement.
Limites d’application : Pressure rating applies only to the specified structure and boundary
36Why choose DOWESTON, and what would make that reasoning evidence-based?
Base the decision on project compliance and documented delivery or service, rather than a slogan. "Active stroke, zero direction and space at both ends" and "Overall mechanical length is not active stroke; end dead zones matter" are important family-specific checks. Claim only benefits supported by the offered product documents and written commitments.
Verification: Request the proposed configuration matching "Mechanical form, active stroke, dead zones and zero direction", test evidence and delivery/service terms. Do not infer unverified performance, approvals, origin or service life.
Limites d’application : Overall mechanical length is not active stroke; end dead zones matter
37How can competing brands be compared beyond a single accuracy or price figure?
Use identical conditions and supply boundaries. Mechanical form, active stroke, dead zones and zero direction; Power, protocol, resolution and update period; Order-specific calibration, hazardous-area and safety-duty documents. Quotes with different ranges, compensation, accessories or calibration scope can conceal material differences.
Verification: Compare "Magnet type, count, orientation and spacing", "Magnet, spacing and nearby ferromagnetic material affect detection" and mounting/acceptance conditions. Separate demonstrated, unverified and inapplicable items; do not claim unproven overall superiority.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
38How should purchasing compare cost without overlooking additions or rework?
Compare complete supply and use-cycle costs, not only the main instrument price. Arrange magnet motion within the active stroke/dead zones and avoid impact; Verify several positions, direction and repeatability within the active stroke using a traceable length reference, recording magnet and mounting; digital resolution is not position accuracy. List the actual installation, supporting equipment, calibration, consumables, downtime and service requirements without assuming any brand is always cheaper.
Verification: Use the same "Mechanical form, active stroke, dead zones and zero direction" configuration and "Pressure construction, temperature, vibration and environment" boundary. Separate equipment, accessories, commissioning and maintenance responsibilities and retain a traceable comparison.
Limites d’application : Pressure rating applies only to the specified structure and boundary
39Why can magnetostrictive sensing provide absolute position?
Magnet position corresponds to wave travel time, allowing each position to be determined without merely accumulating increments. Controller zero, direction and scaling still need correct setup.
Verification: Check recovery at a known intermediate position and verify coordinates and validity, not output presence alone.
Limites d’application : Overall mechanical length is not active stroke; end dead zones matter
40Why is overall sensor length longer than the nominal measuring stroke?
The head, mounting and inactive end regions occupy length, so the full rod is not necessarily measurable. Review overall dimensions and active motion limits together.
Verification: Plot mechanical limits on the drawing and verify the magnet avoids inactive regions and collisions.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
41Can an arbitrary permanent magnet replace the specified position magnet?
Do not assume compatibility. Field direction, strength, dimensions and spacing affect detection; only the specified combination has the documented performance envelope.
Verification: Check magnet part number, orientation and spacing and verify the full stroke and fault states.
Limites d’application : Absolute position still needs zero, direction and controller-coordinate checks
42Why do nearby ferromagnetic parts matter?
Mounting parts can alter the magnetic field and detection conditions. Required nonmagnetic spacers and clearances are model-specific rather than universal.
Verification: Check materials and clearances on the actual drawing and verify the least-favourable positions.
Limites d’application : Pressure rating applies only to the specified structure and boundary
43Which pressure boundary matters inside a hydraulic cylinder?
Review the specific rod, seal, thread and cylinder installation pressure boundary. The head and interfaces need not share the same rating.
Verification: Obtain configuration-specific pressure/temperature and mounting evidence and have the hydraulic design owner review it.
Limites d’application : Overall mechanical length is not active stroke; end dead zones matter
44Does one-micrometre resolution guarantee one-micrometre accuracy?
No. Linearity, repeatability, temperature, installation and reference errors still contribute. A smaller output increment alone does not establish position accuracy.
Verification: Perform multipoint checks with a suitable length reference under representative installation and temperature conditions.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
45Does a matching SSI connector establish replacement compatibility?
No. Word length, coding, clock, format, error bits, direction and update behaviour can differ. The connector establishes only part of the interface.
Verification: Check protocol and pinout and compare raw data, controller position and fault indication at known positions.
Limites d’application : Absolute position still needs zero, direction and controller-coordinate checks
46Can one sensor identify multiple magnets simultaneously?
Only a model explicitly supporting the required count and spacing can do so; verify identity/order, output channels and close-magnet behaviour. Single-magnet devices are not automatically multi-position.
Verification: Obtain the multi-magnet configuration evidence and test minimum spacing, motion and missing-magnet response.
Limites d’application : Pressure rating applies only to the specified structure and boundary
47Does non-contact sensing make a jointed-rod assembly wear-free?
Non-contact describes the sensing principle, not external joints, guides, seals or linkages. Those parts can wear and retain side-load and stroke limits.
Verification: Check joint freedom, alignment and side load and include mechanical parts in maintenance.
Limites d’application : Overall mechanical length is not active stroke; end dead zones matter
48Does lag during fast motion necessarily indicate calibration error?
Not necessarily. Measurement updates, communication and filtering introduce delay, which becomes spatial error at speed. Static accuracy does not establish dynamic synchronisation.
Verification: Record reference and raw output synchronously and separate scale error from timing lag.
Limites d’application : Magnet, spacing and nearby ferromagnetic material affect detection
49What should be checked first for jumps near a stroke end?
Check inactive regions, overtravel, collision and magnet misalignment before communication or scaling. End conditions differ from the centre.
Verification: Approach both ends safely with controlled limits and record position, validity and raw output without impact.
Limites d’application : Absolute position still needs zero, direction and controller-coordinate checks
50Why can controller zero change after replacing a sensor with the same stroke?
Zero direction, inactive regions, mounting reference, magnet and scaling can differ. Equal nominal stroke does not guarantee equal coordinates.
Verification: Compare the complete configuration and dimensions and check direction, scale and faults at known end/mid positions.
Limites d’application : Pressure rating applies only to the specified structure and boundary






