Magnetostrictive level transmitters: 50 selection, application and maintenance questions

50 shared questions for Magnetostrictive level transmitters, covering selection, delivery, maintenance, common questions and evidence-based brand comparisons, with verification actions, limits and sources.

Principes communs · Vérifiez chaque modèle

Shared guidance for this product family. Confirm the complete model and application; family-level guidance is not evidence of a particular product specification or approval.

Les principes généraux s’appliquent en complément de la validation du modèle. Les performances, homologations et alternatives dépendent du code de commande complet et des conditions réelles.

1

What does the Magnetostrictive level transmitters principle establish, and what does it not establish?

A magnetic float produces a torsional pulse in a waveguide; transit time gives float position and level. The principle explains signal generation; it does not establish the range, accuracy, materials or approvals of every model. Review the physical principle and the application limits separately.

Verification: Confirm "Float density and material" and assess "Position accuracy is not total liquid-level error" against the actual application. Record the complete model and document revision used.

Limites d’application : Position accuracy is not total liquid-level error

2

Is the required result measured directly or calculated from other inputs?

Define the quantity to be accepted before selecting a display unit. A magnetic float produces a torsional pulse in a waveguide; transit time gives float position and level. For "Float density and material", document output definitions and conversion or compensation conditions; displaying a value does not make it a direct measurement under all conditions.

Verification: Document the process objective, units and reference conditions. Check "Position accuracy is not total liquid-level error" and list separate inputs and acceptance methods for calculated results.

Limites d’application : Position accuracy is not total liquid-level error

3

Which application information is needed before requesting a quotation?

Prepare at least these five input groups: Float density and material; Rod length and active stroke; Float count and interface objective; Process pressure and mechanics; Output, strapping table and temperature input. Mark unknown items for confirmation instead of substituting a normal point or an assumed default for all conditions.

Verification: Have process, instrumentation and purchasing roles agree the inputs, particularly "Rod length and active stroke". Resolve missing evidence before requesting application confirmation.

Limites d’application : Position accuracy is not total liquid-level error

4

How should the range be chosen rather than copied from a nominal equipment rating?

Select the range from actual operating conditions and permissible error, then check extremes and installation constraints. For this family: Position accuracy is not total liquid-level error Nominal size or maximum equipment rating need not equal the useful measuring interval.

Verification: List minimum, normal, maximum and abnormal conditions. Check "Float count and interface objective" against the documented performance envelope.

Limites d’application : Position accuracy is not total liquid-level error

5

Can a larger turndown claim or display rescaling fix poor low-end performance?

No. Low-end usability depends on the principle, available signal and error mechanisms. The float can still stick or lose buoyancy More display digits, software scaling or a stated turndown cannot remove the original noise or installation error.

Verification: Obtain error definitions and limits at the actual low operating point. Use "Why does mass inventory need density → Level requires a valid volume model and mass additionally requires density. → Keep the rod straight and float travel free and record Process pressure and mechanics" to investigate bias instead of comparing only percent-of-full-scale values.

Limites d’application : The float can still stick or lose buoyancy

6

How should compatibility with the measured object and materials be established?

Use the complete measured object and actual exposure, rather than a material name alone. Process pressure and mechanics Avoid this family-specific misuse: The float can still stick or lose buoyancy For non-wetted equipment, assess loads, target materials, signals and environmental compatibility instead.

Verification: List the actual contact or loading parts, seals, insulation and cleaning conditions. Have the responsible parties assess "Multiple-float interface needs suitable construction".

Limites d’application : Multiple-float interface needs suitable construction

7

Why must abnormal and environmental conditions be listed separately from normal operation?

Normal measurement, temporary excursions and survival limits are different requirements. Multiple-float interface needs suitable construction Start-up, cleaning, impacts, power interruption or abnormal environments can determine the necessary construction and protection.

Verification: Complete the worst-case conditions using "Output, strapping table and temperature input" and check "Volume and mass require additional valid models". Separate continuous operating limits from temporary limits in the specification.

Limites d’application : Volume and mass require additional valid models

8

Can the published instrument accuracy be used as the installed system accuracy?

Not without assessment. Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. The installed system also includes object, mounting, signal conversion, environmental and reference effects. Derived results additionally depend on the relevant input uncertainties.

Verification: Agree actual test points, installation conditions and the acceptance reference. Check "Keep the rod straight and float travel free" and document the system error or uncertainty basis.

Limites d’application : The float can still stick or lose buoyancy

9

How should response time, filtering and a stable display be balanced?

A stable indication and fast change detection involve a trade-off; filtering cannot repair incorrect installation or real process variation. How should temperature-related changes be separated → Distinguish real expansion, immersion changes and reference/mechanical effects. → Verify communication variables and strapping table and record Float count and interface objective Review the complete chain when fast response matters, not merely the display refresh rate.

Verification: Define the shortest relevant event and acceptable delay. Check "Record datum and inactive zones" and verify local output, display and receiving-system response using a controlled change.

Limites d’application : Multiple-float interface needs suitable construction

10

Which typical applications fit, and which require a specific engineering review?

Typical contexts include: High-resolution tank level; Clean-liquid interface; Inventory support monitoring. Similar application labels do not establish equivalent conditions. In particular, assess "Volume and mass require additional valid models" before relying on another installation as proof.

Verification: Select the nearest application and compare "Float density and material" and "Output, strapping table and temperature input". Obtain written confirmation where published application limits are exceeded.

Limites d’application : Volume and mass require additional valid models

11

How should a complete order code be defined without unspecified standard options?

Translate required functions, performance and physical interfaces into verifiable options. Float density and material; Rod length and active stroke. Options affecting suitability or supply scope should be explicit; terms such as standard or same as existing are insufficient.

Verification: Check the complete order code and selection sheet, especially "Float count and interface objective". List accessories, documents, calibration and delivery boundaries separately.

Limites d’application : Position accuracy is not total liquid-level error

12

Which mounting and mechanical layout checks belong before ordering?

Keep the rod straight and float travel free The installation drawing must match the available space and process or mechanical structure. Access for fitting and servicing should be established before delivery.

Verification: Review a dimensioned, oriented site drawing. Use "Process pressure and mechanics" and "Multiple-float interface needs suitable construction" to confirm connections, support, removal access and safe isolation.

Limites d’application : Multiple-float interface needs suitable construction

13

How can supporting infrastructure prevent an instrument that fits but cannot be used?

Verify float orientation and stop collars Supporting conditions are part of the measurement system. Matching mechanical connections or signal names alone do not establish power, I/O, grounding or configuration compatibility.

Verification: Confirm "Keep the rod straight and float travel free" and "Verify output, failure state and receiving-system compatibility" against actual terminals, loops and receiving-system settings.

Limites d’application : The float can still stick or lose buoyancy

14

What is a sensible commissioning sequence before changing correction factors?

Check identity, installation and basic conditions first, then status, output and process response. Record datum and inactive zones Preserve original evidence for unexplained anomalies instead of concealing them with zero or factor adjustments.

Verification: Record factory settings and initial status. Investigate "Why can communication work while level is frozen → The float or buoyancy may fail despite healthy communications. → Record datum and inactive zones and record Rod length and active stroke" step by step and change parameters only after identifying the cause and using an authorised procedure.

Limites d’application : Multiple-float interface needs suitable construction

15

Do identical output units or interface names establish connection compatibility?

No. Establish the represented object and reference conditions: Float density and material. Electrical equipment also needs loop type, scaling, failure behaviour and protocol details checked. Mechanical indicators require clear boundaries between indication and remote-transmission accessories.

Verification: Check the receiving-system variable against "Float density and material" and verify limits, units and abnormal states with the actual equipment. Record wiring, configuration and end-to-end checks against "Verify float orientation and stop collars".

Limites d’application : The float can still stick or lose buoyancy

16

What should a calibration report contain to be relevant to the application?

Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. The report should identify the delivered instrument, measured quantity, conditions, method and results. A general conformity certificate does not establish performance for every option or operating condition.

Verification: Check serial number, points, units, reference equipment and traceability. Compare "Rod length and active stroke" with the calibrated conditions and agree separate acceptance where they differ.

Limites d’application : The float can still stick or lose buoyancy

17

How can delivery and site acceptance use reproducible pass criteria?

Verify communication variables and strapping table Agree criteria before testing, including range, conditions, error definition and treatment of anomalies. Similar-looking readings or an unsuitable portable reference are not sufficient acceptance evidence.

Verification: Choose an appropriate reference using "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment.". Record "Float density and material" and test conditions; investigate "Why does mass inventory need density → Level requires a valid volume model and mass additionally requires density. → Keep the rod straight and float travel free and record Process pressure and mechanics" before deciding on rework or recalibration.

Limites d’application : The float can still stick or lose buoyancy

18

What belongs in the quotation and agreement for a non-standard application?

Define why the standard supply is insufficient, the required verification and the responsible parties. Volume and mass require additional valid models; Volume and mass require additional valid models. Additional materials, construction, documents or tests depend on actual requirements.

Verification: Attach "Output, strapping table and temperature input" and the deviations. Obtain technical confirmation, additional charges, delivery conditions and acceptance methods; unknown requirements must not be assumed satisfied.

Limites d’application : Volume and mass require additional valid models

19

Where should investigation start when there is no valid reading or output?

Why can communication work while level is frozen → The float or buoyancy may fail despite healthy communications. → Record datum and inactive zones and record Rod length and active stroke Distinguish the actual measured condition from device-state and readout or transmission faults. Do not immediately interpret missing data as sensor failure or a zero process value.

Verification: Under appropriate safe isolation, check "Verify float orientation and stop collars". Compare local and receiving-end status and record when the fault appeared.

Limites d’application : Position accuracy is not total liquid-level error

20

How can unstable readings be separated from genuine process variation?

How should temperature-related changes be separated → Distinguish real expansion, immersion changes and reference/mechanical effects. → Verify communication variables and strapping table and record Float count and interface objective Compare independent process evidence and raw signals before deciding whether installation, interference or equipment is responsible. More filtering can hide a real abnormal event.

Verification: Keep conditions comparable and record correlation with process or equipment events. Check "Keep the rod straight and float travel free" and change one factor at a time.

Limites d’application : Multiple-float interface needs suitable construction

21

How should a persistent high or low bias be investigated before changing factors?

Why does mass inventory need density → Level requires a valid volume model and mass additionally requires density. → Keep the rod straight and float travel free and record Process pressure and mechanics Systematic bias can arise from units, reference conditions, configuration, installation or the reference method. An unexplained correction can move one operating-point error to other conditions.

Verification: Align quantities, time bases and units first. Review the reference using "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment." and confirm that "Rod length and active stroke" matches the configuration.

Limites d’application : The float can still stick or lose buoyancy

22

When is it appropriate to adjust a drifting zero or reference position?

Can a replacement module blindly reuse a strapping table → No. Confirm vessel identity, units, datum and table version. → Verify float orientation and stop collars and record Output, strapping table and temperature input Establish a genuine, stable reference condition that meets the method requirements before considering adjustment. Some instruments have no freely adjustable site zero.

Verification: Check "Record datum and inactive zones" and "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment." and retain before-and-after results. If the conditions cannot be established, remove external effects or use a qualified service.

Limites d’application : Multiple-float interface needs suitable construction

23

Which evidence helps diagnose intermittent alarms or failures?

Does absolute position eliminate verification → No. Float, installation and inventory models still need validation. → Record datum and inactive zones and record Float density and material Intermittent faults need correlated event records, not just a normal display after recovery. Review alarm settings, communication status and actual process abnormalities separately.

Verification: Retain time, status codes, raw trends and the contemporaneous "Output, strapping table and temperature input". Compare "Verify float orientation and stop collars" and "Record datum and inactive zones" to locate the failing link.

Limites d’application : Volume and mass require additional valid models

24

Why should repeated failures trigger a cause review instead of another identical replacement?

Repeated failures warrant a common-cause assessment. Volume and mass require additional valid models If the external conditions remain unchanged, an identical construction or installation can experience the same failure again.

Verification: Summarise failed parts, service time and "Output, strapping table and temperature input". Check "Keep the rod straight and float travel free" and "Multiple-float interface needs suitable construction" and establish corrective action before selecting repair or redesign.

Limites d’application : Multiple-float interface needs suitable construction

25

What distinguishes a site comparison, an adjustment and a calibration?

Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. A comparison identifies differences; adjustment changes indication or parameters; calibration establishes a reference relationship under stated conditions. They are not interchangeable claims.

Verification: Define what performance and evidence must be established, using conditions relevant to "Rod length and active stroke". Retain original and adjusted results, references and responsibility records.

Limites d’application : The float can still stick or lose buoyancy

26

What must be checked again after replacing an instrument with the same basic model?

The same basic model does not establish identical options, software, calibration or accessories. Verify output, failure state and receiving-system compatibility; Confirm certificates, calibration and site change approval in writing. Previous system operation does not remove the need to verify a replacement.

Verification: Compare full order codes and revisions. Recheck critical points, failure states and interfaces using "Verify communication variables and strapping table" before handover.

Limites d’application : Volume and mass require additional valid models

27

Can every published maximum rating be achieved simultaneously?

No. Position accuracy is not total liquid-level error Maximum values usually relate to particular options and conditions. Temperature, load, pressure, materials, speed or signal conditions may constrain one another.

Verification: Review "Float count and interface objective" and "Output, strapping table and temperature input" together. Obtain confirmation for the combined conditions instead of assembling unrelated maxima from separate pages.

Limites d’application : Position accuracy is not total liquid-level error

28

Does a missing signal or zero indication establish that the process value is zero?

No. Why can communication work while level is frozen → The float or buoyancy may fail despite healthy communications. → Record datum and inactive zones and record Rod length and active stroke Indication, measurement and transmission have distinct possible failure modes. Also consider "Position accuracy is not total liquid-level error"; establish the actual process condition independently.

Verification: Check available status or failure indications and "Keep the rod straight and float travel free". For interlocks, follow the complete safety design rather than substituting a zero value for diagnosis.

Limites d’application : Position accuracy is not total liquid-level error

29

Does one acceptable test point establish compliance across the working range?

No. Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. Test points and directions must reflect the working interval, relevant error mechanisms and acceptance purpose. Multiple points, reversal or load tests depend on the method.

Verification: Define acceptance coverage against "Rod length and active stroke" and include critical operating points. Mark conditions outside the tests as unverified.

Limites d’application : The float can still stick or lose buoyancy

30

Are the largest range, highest accuracy class and most options always preferable?

Not necessarily. Options should serve the required objective; excess configuration can add cost, complexity or incompatibility. The float can still stick or lose buoyancy; The float can still stick or lose buoyancy. Establish essential requirements before comparing optional benefits.

Verification: Document the objective in "Float density and material" and why "Float density and material" is needed. Compare performance at actual working points rather than one headline metric.

Limites d’application : The float can still stick or lose buoyancy

31

Can every maintenance or recalibration interval simply be fixed at one year?

Not independently of risk and history. Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. Intervals depend on applicable law or contract, conditions, drift, maintenance and failure evidence. Generic advice cannot replace mandatory requirements.

Verification: Use "Can a replacement module blindly reuse a strapping table → No. Confirm vessel identity, units, datum and table version. → Verify float orientation and stop collars and record Output, strapping table and temperature input" and "Volume and mass require additional valid models" to establish and review an initial plan. Retain the justification and approval for interval changes.

Limites d’application : Volume and mass require additional valid models

32

Can parts from different brands be mixed if their physical interfaces fit?

Physical fit is insufficient. Rod length and active stroke; Keep the rod straight and float travel free. Matching, materials, signals, calibration and approval boundaries can change with the combination.

Verification: Check the complete combination against "Verify float orientation and stop collars" and obtain compatibility and acceptance evidence. An unconfirmed assembly must not be described as an approved system.

Limites d’application : The float can still stick or lose buoyancy

33

Does a hazardous-area, hygienic or safety label establish suitability for that duty?

Check the exact order configuration and valid documents rather than a series name. Confirm certificates, calibration and site change approval in writing "Volume and mass require additional valid models" also matters; certificates, installation conditions and restrictions together define suitability.

Verification: Obtain certificate identifiers, covered models and special conditions and match them to the site. Similar names do not grant functional-safety or legal-metrology approval.

Limites d’application : Volume and mass require additional valid models

34

What evidence makes the final result acceptable, reproducible and sustainable?

Establish the chain from quantity definition and application limits through configuration, mounting, reference and operating status. Verify communication variables and strapping table A normal indication or brochure alone cannot demonstrate continuing system reliability.

Verification: Put "Float density and material", "Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment." and "Does absolute position eliminate verification → No. Float, installation and inventory models still need validation. → Record datum and inactive zones and record Float density and material" into the technical, acceptance and maintenance records, with responsibility for reviewing excursions.

Limites d’application : Volume and mass require additional valid models

35

Can a DOWESTON model replace an installed instrument from another brand?

Possibly, after a full configuration and application comparison. A basic model name or matching output is not proof of equivalent replacement. Float density and material; Rod length and active stroke; Keep the rod straight and float travel free. Record conclusions on material differences.

Verification: Provide the original full order code, data sheet and site conditions. Check "Verify output, failure state and receiving-system compatibility" and "Confirm certificates, calibration and site change approval in writing" and obtain the necessary test and approval evidence before replacement.

Limites d’application : Volume and mass require additional valid models

36

Why choose DOWESTON, and what would make that reasoning evidence-based?

Base the decision on project compliance and documented delivery or service, rather than a slogan. "Float density and material" and "Position accuracy is not total liquid-level error" are important family-specific checks. Claim only benefits supported by the offered product documents and written commitments.

Verification: Request the proposed configuration matching "Float density and material", test evidence and delivery/service terms. Do not infer unverified performance, approvals, origin or service life.

Limites d’application : Position accuracy is not total liquid-level error

37

How can competing brands be compared beyond a single accuracy or price figure?

Use identical conditions and supply boundaries. Float density and material; Keep the rod straight and float travel free; Confirm certificates, calibration and site change approval in writing. Quotes with different ranges, compensation, accessories or calibration scope can conceal material differences.

Verification: Compare "Rod length and active stroke", "The float can still stick or lose buoyancy" and mounting/acceptance conditions. Separate demonstrated, unverified and inapplicable items; do not claim unproven overall superiority.

Limites d’application : The float can still stick or lose buoyancy

38

How should purchasing compare cost without overlooking additions or rework?

Compare complete supply and use-cycle costs, not only the main instrument price. Keep the rod straight and float travel free; Use a traceable reference appropriate to the principle, compare several application points and record conditions before and after adjustment. List the actual installation, supporting equipment, calibration, consumables, downtime and service requirements without assuming any brand is always cheaper.

Verification: Use the same "Float density and material" configuration and "Output, strapping table and temperature input" boundary. Separate equipment, accessories, commissioning and maintenance responsibilities and retain a traceable comparison.

Limites d’application : Volume and mass require additional valid models

39

Is magnetostriction identical to a reed-chain level sensor?

No. Pulse timing and discrete reed/resistance sensing are different mechanisms. Verify Keep the rod straight and float travel free and record Float density and material. Position accuracy is not total liquid-level error. Confirm the exact model and record the result before changing settings.

Verification: Keep the rod straight and float travel free and record Float density and material

Limites d’application : Position accuracy is not total liquid-level error

40

Why can precise position still yield a level offset?

Float immersion, density and datum contribute additional error. Verify Verify float orientation and stop collars and record Rod length and active stroke. The float can still stick or lose buoyancy. Confirm the exact model and record the result before changing settings.

Verification: Verify float orientation and stop collars and record Rod length and active stroke

Limites d’application : The float can still stick or lose buoyancy

41

Does adding a float enable every interface measurement?

No. Buoyancy, multi-magnet support and phase conditions must be suitable. Verify Record datum and inactive zones and record Float count and interface objective. Multiple-float interface needs suitable construction. Confirm the exact model and record the result before changing settings.

Verification: Record datum and inactive zones and record Float count and interface objective

Limites d’application : Multiple-float interface needs suitable construction

42

Is a bent rod acceptable?

Bending can restrict the float and stress the assembly; follow the specified limits. Verify Verify communication variables and strapping table and record Process pressure and mechanics. Volume and mass require additional valid models. Confirm the exact model and record the result before changing settings.

Verification: Verify communication variables and strapping table and record Process pressure and mechanics

Limites d’application : Volume and mass require additional valid models

43

What if the float is reversed?

Magnet location and buoyancy geometry may be directional. Verify Keep the rod straight and float travel free and record Output, strapping table and temperature input. Position accuracy is not total liquid-level error. Confirm the exact model and record the result before changing settings.

Verification: Keep the rod straight and float travel free and record Output, strapping table and temperature input

Limites d’application : Position accuracy is not total liquid-level error

44

Why is total rod length not the active range?

Inactive zones, collars and float dimensions limit usable travel. Verify Verify float orientation and stop collars and record Float density and material. The float can still stick or lose buoyancy. Confirm the exact model and record the result before changing settings.

Verification: Verify float orientation and stop collars and record Float density and material

Limites d’application : The float can still stick or lose buoyancy

45

Why can communication work while level is frozen?

The float or buoyancy may fail despite healthy communications. Verify Record datum and inactive zones and record Rod length and active stroke. Multiple-float interface needs suitable construction. Confirm the exact model and record the result before changing settings.

Verification: Record datum and inactive zones and record Rod length and active stroke

Limites d’application : Multiple-float interface needs suitable construction

46

How should temperature-related changes be separated?

Distinguish real expansion, immersion changes and reference/mechanical effects. Verify Verify communication variables and strapping table and record Float count and interface objective. Volume and mass require additional valid models. Confirm the exact model and record the result before changing settings.

Verification: Verify communication variables and strapping table and record Float count and interface objective

Limites d’application : Volume and mass require additional valid models

47

Why does mass inventory need density?

Level requires a valid volume model and mass additionally requires density. Verify Keep the rod straight and float travel free and record Process pressure and mechanics. Position accuracy is not total liquid-level error. Confirm the exact model and record the result before changing settings.

Verification: Keep the rod straight and float travel free and record Process pressure and mechanics

Limites d’application : Position accuracy is not total liquid-level error

48

Can a replacement module blindly reuse a strapping table?

No. Confirm vessel identity, units, datum and table version. Verify Verify float orientation and stop collars and record Output, strapping table and temperature input. The float can still stick or lose buoyancy. Confirm the exact model and record the result before changing settings.

Verification: Verify float orientation and stop collars and record Output, strapping table and temperature input

Limites d’application : The float can still stick or lose buoyancy

49

Does absolute position eliminate verification?

No. Float, installation and inventory models still need validation. Verify Record datum and inactive zones and record Float density and material. Multiple-float interface needs suitable construction. Confirm the exact model and record the result before changing settings.

Verification: Record datum and inactive zones and record Float density and material

Limites d’application : Multiple-float interface needs suitable construction

50

What matters in a magnetostrictive replacement?

Compare float conditions, active range, multi-float support, variables and inventory model. Verify Verify communication variables and strapping table and record Rod length and active stroke. Volume and mass require additional valid models. Confirm the exact model and record the result before changing settings.

Verification: Verify communication variables and strapping table and record Rod length and active stroke

Limites d’application : Volume and mass require additional valid models

Appliquez ces connaissances à la sélection

Clients et achats

Vérifiez les conditions réelles et les critères de réception dans l’article et la documentation du produit. Soumettez les points ouverts au service technique DOWESTON.

Équipes commerciales et techniques

Notez les questions du client et ses conditions de service. Vérifiez la plage, les raccordements et les conditions d’utilisation dans la documentation du modèle sélectionné.

Transformez les questions en critères de sélection

Relevez le fluide, les raccordements, le montage et les critères de réception du produit, puis examinez les points ouverts avec DOWESTON.

Choisir un produit et préparer les conditions de service
Pas encore connecté à DOWESTON ?
Créez un compte pour commencer la sélection, consulter les prix et recevoir notre lettre d'information sur les dernières nouveautés.
Produits et services
Doweston propose une gamme de services pour vous aider à construire rapidement vos systèmes d'instrumentation automatisés. Contactez-nous pour en savoir plus.
Prêt à acheter ?
Si vous souhaitez acheter des produits,
contactez simplement notre équipe commerciale — nous serons ravis de vous aider.
Qui sommes-nous
DOWESTON fournit des solutions de mesure précises et fiables
— des produits de détection et de capteurs fiables dans tous les domaines !
Une demande de service ?
Si vous souhaitez optimiser votre production et réduire les arrêts,
nous pouvons vous aider à choisir les pièces de rechange et les services adaptés.
Modifier la configuration

Nom du produit

Marque

Modèle

Confirmer les modifications Annuler
Votre écran est peut-être trop petit pour une navigation optimale.
Nous vous recommandons de continuer sur un ordinateur,
ou contactez immédiatement un ingénieur pour votre sélection !
Service plus rapide ? Appelez le
400-888-4436
Continuer la navigation