Parta de su proceso y encuentre el instrumento adecuado
Aprenda los principios de medición, compruebe las condiciones del proceso, configure productos y guarde recursos técnicos.

La edición en español aún no está disponible. A continuación se muestra la versión completa en inglés.

← Volver a la base de conocimientos
Selección y aplicaciones3 min de lecturaIdioma del contenido: inglésActualizado 23 de octubre de 2026

Electromagnetic flowmeters: how to check the minimum liquid conductivity

Use conductivity at the actual process temperature and concentration to check the model requirement. The name of an aqueous solution alone is insufficient to establish measurability.

Check the operating range

Check the model against the liquid conductivity at actual operating temperatures and concentrations. Identifying the fluid as an aqueous solution does not establish that the meter can measure it.

Include the lowest concentration and the temperature extremes. A single laboratory result for the formulation at room temperature cannot represent the full process range.

What to verify and when it applies

The conductive liquid, the electrode interface and the reference connection form the path for a weak signal. Check that the liquid maintains effective electrical contact, then look for electrode fouling or changes in the reference connection. A reading during one process stage shows that there is a signal at that stage. It does not establish an equal signal margin for every stage.

Obtain both the conductivity of the actual process liquid and the minimum conductivity specified for the flowmeter. To establish interchangeability, compare mechanical connections, electrical connections, functions and calibration compatibility. Similar appearance or connections cover only part of the comparison. Check the software options and accessories against the supply records. When the configuration is finalized, retain the full model code, drawings and verification requirements. After servicing, confirm which elements of the original configuration the replacement affected.

How to check the application

  • Obtain the conductivity of the actual liquid and the meter’s minimum requirement. Record available flow readings and electrode or empty-pipe diagnostics. Identify which data were actually obtained and which functions are documented for this meter.
  • List the minimum, typical and most unfavorable conductivity conditions, recording their durations and the source of each value.
  • Compare before and after conditions using a reference suitable for the instrument and the application. Keep the original conductivity-related settings and process conditions on record. Address one factor at a time based on the evidence.

Example: unstable readings as conductivity drops

Suppose a pure-water process gives an unstable signal as conductivity falls. If the liquid at its lowest concentration falls below the model requirement, stable readings at a higher concentration cannot establish suitability for the entire formulation cycle.

First compare the current process conditions with those used to select the original meter.

Record the result and the delivered configuration

State the actual conductivity results beside the meter’s minimum requirement. Record which operating conditions were covered, the basis for the comparison and any open items. Keep the original measurements and configuration with the report. A test that simulates only the output cannot verify the parts of the measurement chain it bypasses.

This is an illustrative case. Follow the actual model limits and site procedures. Confirm the supplied specification and certification from the Doweston product documentation.

Aplique estos conocimientos a la selección

Clientes y compras

Compruebe las condiciones reales y los criterios de aceptación con el artículo y la documentación del producto. Envíe las cuestiones pendientes al servicio técnico de DOWESTON.

Equipos comerciales y técnicos

Anote las preguntas del cliente y sus condiciones de servicio. Compruebe el rango, las conexiones y las condiciones de uso en la documentación del modelo seleccionado.

Convierta las preguntas en criterios de selección

Reúna los datos del fluido, las conexiones, la instalación y los criterios de aceptación del producto, y revise los puntos pendientes con DOWESTON.

Elegir un producto y preparar las condiciones de servicio
¿Aún no ha iniciado sesión en DOWESTON?
Cree una cuenta para empezar a seleccionar, consultar precios y recibir nuestro boletín con las últimas novedades.
Productos y servicios
Doweston ofrece una gama de servicios para ayudarle a construir rápidamente sistemas de instrumentación automatizada. Contáctenos para más información.
¿Listo para comprar?
Si desea comprar productos,
solo contacte con nuestro equipo de ventas — estaremos encantados de ayudarle.
Quiénes somos
DOWESTON ofrece soluciones de medición precisas y fiables
¡productos de detección y sensores fiables para todos los sectores!
¿Necesita servicio?
Si desea optimizar la producción y reducir los parones,
podemos ayudarle a elegir las piezas de repuesto y los productos de servicio adecuados.
Editar configuración

Nombre del producto

Marca

Modelo

Confirmar cambios Cancelar
Su pantalla puede ser demasiado pequeña para una mejor experiencia.
Le recomendamos continuar en un ordenador,
¡o contacte de inmediato con un ingeniero para su selección!
¿Servicio más rápido? Llame al
400-888-4436
Seguir navegando