Electromagnetic flowmeters: Can they measure oils and gases?

Oils and gases are generally nonconductive and do not meet the requirements of conventional electromagnetic flow measurement. Assess other measurement principles for these media.

Start an application checklist

Direct answer

Oils and gases are generally nonconductive and do not meet the requirements of conventional electromagnetic flow measurement. Assess other measurement principles for these media.

With no stable, continuous conductive phase, conventional electrodes cannot reliably pick up the induced voltage. Changing the units does not address that physical limitation.

What to check and when it applies

Compare actual capabilities under identical operating conditions. Check the most demanding condition separately from long-term operation to determine whether the limitation lies in the measurement, mechanical installation or interface. If candidate data use different media or reference conditions, align the assumptions before comparing. Do not combine maxima from different conditions.

The question for an electromagnetic flowmeter is whether the continuous phase is a conductive liquid. When judging interchangeability, check mechanical, electrical and functional compatibility as well as calibration pairing. Matching housings or connections establish only part of that compatibility. Record the software options and accessories actually supplied. When freezing a configuration, retain the full model, drawings and verification requirements. After maintenance, check which parts of the original configuration the replacement affected.

How to perform this check

  • First check whether the continuous phase is a conductive liquid. Record flow, electrode information and empty-pipe diagnostics. Mark which data you actually obtained. Treat undocumented diagnostics or functions as unconfirmed.
  • Tabulate the minimum, usual and most demanding operating conditions relevant to measuring the oil or gas. Indicate the duration and source of the data for each condition.
  • Compare conditions before and after checking whether the continuous phase is a conductive liquid. Select a reference suited to the equipment and conditions. Keep the original instrument configuration and process conditions during the comparison. Change only one factor at a time, guided by the evidence.

Example: how to draw a conclusion

Consider a customer asking to measure compressed air with an electromagnetic meter. If the medium under consideration is an insulating oil, increasing the current range or selecting mass units will likewise not provide the conductive path that a conventional electromagnetic meter requires.

Start by comparing the current conditions with the conditions used to select the original meter.

Confirm the findings and document the handover

The conclusion should answer whether the oil or gas can be measured. Record the evidence on whether the continuous phase is a conductive liquid, which conditions were covered, the reference used and what remains to be confirmed. Retain the original records and configuration. A single simulation at the output cannot be signed off as a pass for parts of the measurement chain that were not tested.

This is an illustrative example. Use the actual model specifications and site procedures for limits and operating conditions. Reference material does not replace Doweston supply specifications or certifications.

Apply this knowledge to product selection

Customers and procurement

Check actual application and acceptance requirements against the article and product documentation. Bring open questions to DOWESTON for technical review.

Sales and technical teams

Record customer questions with application conditions. Verify range, interfaces and operating requirements against the selected model documentation.

Turn questions into application requirements

Collect application, connection, installation and acceptance requirements for the selected product, then review open points with DOWESTON.

Start an application checklist
Not signed in to DOWESTON?
Create an account to start selecting products, check prices, and receive our newsletter on the latest products and trends.
Products & Services
Doweston offers a range of services to help you quickly build automated instrumentation systems. Contact us to learn more.
Ready to buy?
If you would like to purchase products,
simply contact our sales team — we are happy to help.
Who we are
DOWESTON delivers accurate and reliable measurement solutions
— trusted sensing and detection products for every industry!
Need service?
If you want to optimize production and reduce downtime,
we can help you choose the right spare parts and service products.
Edit Configuration

Product name

Brand

Model

Confirm Changes Cancel
Your screen may be too small for the best experience.
We recommend using a computer,
or contact an engineer right away for selection support!
Need faster service? Call
400-888-4436
Continue Browsing