Start with your process. Find the right instrument.
Learn measurement principles, check process conditions, configure products and save technical resources.

A complete English edition of this article has not been published. The complete available Chinese version is shown below.

← Back to knowledge hub
Selection and applications5 min readContent language: ChineseUpdated 23 October 2026

二线、三线压力传感器,以及 PLC 有源无源输入,怎样匹配?

线数和电流信号不是同一概念,先沿回路确认由谁供电,再按图接线。

不能只按颜色接线

二线电流型通常通过同一回路供电和传信号,三线型则有独立供电与信号连接;具体形式应以该配置接线图为准。线色和插头外观不是通用针脚标准,旧件接到哪里不能直接成为新件的依据。

先画出电源和负载

PLC 输入可能提供回路电源,也可能只接收信号。“有源”“无源”在不同资料中的口头用法可能混淆,最可靠的方法是标出供电正负、信号路径、公共端和输入负载。不能让两处电源未经核对相接,也不能指望无供电回路自动工作。

通电前确认三份文件

准备传感器针脚图、采集卡接线说明和实际回路草图,交由电气人员核对。向道威斯顿询价时附上卡件输入方式,可减少选错输出版本。调试应从电源、端子到采集值逐段验证,禁止靠反复调换导线试出“能显示”的接法。

现场核对:画出电流回路后再接线

  • 标出哪一设备给回路提供电压,哪一设备只接收信号,并记录各自端子的定义。
  • 核对二线或三线具体形式、针脚与极性,不能由线色或插头外观判断。
  • 检查公共参考端及隔离要求,区分传感器电源、采集卡输入和其他串联设备。
  • 接线完成后按程序验证端电压、输出与显示,任何改线先执行相应隔离措施。

假设例子:三根现场线不代表新件必须是三线制

假设设备原来预留三根线,维修人员看到新件只有两个端子便认为少了一个信号端。实际上可用导线数量和传感器接线制不是一回事,需要回到电源、回路负载与卡件输入图确认。多余导线怎样处理也应按电气规范,不能随意把它接到外壳或公共端。

销售应请客户提供实际回路图,追问卡件是否提供电源、是否有显示器或隔离器,以及原件连接方式。若资料中的“有源”“无源”表述不清,就把电源和电流路径画出来确认,不用口头术语猜测。这个情景没有给出通用端子接法,所有实际接线仍以所订配置文件为准。

Apply this knowledge to product selection

Customers and procurement

Check actual application and acceptance requirements against the article and product documentation. Bring open questions to DOWESTON for technical review.

Sales and technical teams

Record customer questions with application conditions. Verify range, interfaces and operating requirements against the selected model documentation.

Turn questions into application requirements

Collect application, connection, installation and acceptance requirements for the selected product, then review open points with DOWESTON.

Choose a product and prepare requirements
Not signed in to DOWESTON?
Create an account to start selecting products, check prices, and receive our newsletter on the latest products and trends.
Products & Services
Doweston offers a range of services to help you quickly build automated instrumentation systems. Contact us to learn more.
Ready to buy?
If you would like to purchase products,
simply contact our sales team — we are happy to help.
Who we are
DOWESTON delivers accurate and reliable measurement solutions
— trusted sensing and detection products for every industry!
Need service?
If you want to optimize production and reduce downtime,
we can help you choose the right spare parts and service products.
Edit Configuration

Product name

Brand

Model

Confirm Changes Cancel
Your screen may be too small for the best experience.
We recommend using a computer,
or contact an engineer right away for selection support!
Need faster service? Call
400-888-4436
Continue Browsing