Start with your process. Find the right instrument.
Learn measurement principles, check process conditions, configure products and save technical resources.
← Back to knowledge hub
Selection and applications3 min readContent language: EnglishUpdated 23 October 2026

Electromagnetic flowmeters: how to check the minimum liquid conductivity

Use conductivity at the actual process temperature and concentration to check the model requirement. The name of an aqueous solution alone is insufficient to establish measurability.

Check the operating range

Check the model against the liquid conductivity at actual operating temperatures and concentrations. Identifying the fluid as an aqueous solution does not establish that the meter can measure it.

Include the lowest concentration and the temperature extremes. A single laboratory result for the formulation at room temperature cannot represent the full process range.

What to verify and when it applies

The conductive liquid, the electrode interface and the reference connection form the path for a weak signal. Check that the liquid maintains effective electrical contact, then look for electrode fouling or changes in the reference connection. A reading during one process stage shows that there is a signal at that stage. It does not establish an equal signal margin for every stage.

Obtain both the conductivity of the actual process liquid and the minimum conductivity specified for the flowmeter. To establish interchangeability, compare mechanical connections, electrical connections, functions and calibration compatibility. Similar appearance or connections cover only part of the comparison. Check the software options and accessories against the supply records. When the configuration is finalized, retain the full model code, drawings and verification requirements. After servicing, confirm which elements of the original configuration the replacement affected.

How to check the application

  • Obtain the conductivity of the actual liquid and the meter’s minimum requirement. Record available flow readings and electrode or empty-pipe diagnostics. Identify which data were actually obtained and which functions are documented for this meter.
  • List the minimum, typical and most unfavorable conductivity conditions, recording their durations and the source of each value.
  • Compare before and after conditions using a reference suitable for the instrument and the application. Keep the original conductivity-related settings and process conditions on record. Address one factor at a time based on the evidence.

Example: unstable readings as conductivity drops

Suppose a pure-water process gives an unstable signal as conductivity falls. If the liquid at its lowest concentration falls below the model requirement, stable readings at a higher concentration cannot establish suitability for the entire formulation cycle.

First compare the current process conditions with those used to select the original meter.

Record the result and the delivered configuration

State the actual conductivity results beside the meter’s minimum requirement. Record which operating conditions were covered, the basis for the comparison and any open items. Keep the original measurements and configuration with the report. A test that simulates only the output cannot verify the parts of the measurement chain it bypasses.

This is an illustrative case. Follow the actual model limits and site procedures. Confirm the supplied specification and certification from the Doweston product documentation.

Apply this knowledge to product selection

Customers and procurement

Check actual application and acceptance requirements against the article and product documentation. Bring open questions to DOWESTON for technical review.

Sales and technical teams

Record customer questions with application conditions. Verify range, interfaces and operating requirements against the selected model documentation.

Turn questions into application requirements

Collect application, connection, installation and acceptance requirements for the selected product, then review open points with DOWESTON.

Choose a product and prepare requirements
Not signed in to DOWESTON?
Create an account to start selecting products, check prices, and receive our newsletter on the latest products and trends.
Products & Services
Doweston offers a range of services to help you quickly build automated instrumentation systems. Contact us to learn more.
Ready to buy?
If you would like to purchase products,
simply contact our sales team — we are happy to help.
Who we are
DOWESTON delivers accurate and reliable measurement solutions
— trusted sensing and detection products for every industry!
Need service?
If you want to optimize production and reduce downtime,
we can help you choose the right spare parts and service products.
Edit Configuration

Product name

Brand

Model

Confirm Changes Cancel
Your screen may be too small for the best experience.
We recommend using a computer,
or contact an engineer right away for selection support!
Need faster service? Call
400-888-4436
Continue Browsing