The requested language edition has not been published. The complete available English version is shown below.
← Back to knowledge hubWeighing indicators and transmitters: 50 selection, application and maintenance questions
50 shared questions for Weighing indicators and transmitters, covering selection, delivery, maintenance, common questions and evidence-based brand comparisons, with verification actions, limits and sources.
Retain your engineering references
Keep a draft in this browser, then manually import it in My library after signing in.
Accounts follow the existing registration and approval process. Saving knowledge does not automatically unlock pricing or other commercial permissions.
Shared guidance for this product family. Confirm the complete model and application; family-level guidance is not evidence of a particular product specification or approval.
通用原理不能代替具体型号的技术确认;产品性能、认证和替代关系以完整订货号及实际工况为准。
1What does the Weighing indicators and transmitters principle establish, and what does it not establish?
A weighing indicator or transmitter excites, amplifies, samples and scales bridge signals. Overall weighing performance also depends on the load cells, load path, calibration and dynamic processing. The principle explains signal generation; it does not establish the range, accuracy, materials or approvals of every model. Review the physical principle and the application limits separately.
Verification: Confirm "Number of cells, bridge resistance, mV/V and nominal capacities" and assess "ADC bits and display divisions do not establish usable accuracy or stable resolution" against the actual application. Record the complete model and document revision used.
适用边界:ADC bits and display divisions do not establish usable accuracy or stable resolution
2Is the required result measured directly or calculated from other inputs?
Define the quantity to be accepted before selecting a display unit. A weighing indicator or transmitter excites, amplifies, samples and scales bridge signals. Overall weighing performance also depends on the load cells, load path, calibration and dynamic processing. For "Number of cells, bridge resistance, mV/V and nominal capacities", document output definitions and conversion or compensation conditions; displaying a value does not make it a direct measurement under all conditions.
Verification: Document the process objective, units and reference conditions. Check "Promising effective resolution directly from a 24-bit label" and list separate inputs and acceptance methods for calculated results.
适用边界:Promising effective resolution directly from a 24-bit label
3Which application information is needed before requesting a quotation?
Prepare at least these five input groups: Number of cells, bridge resistance, mV/V and nominal capacities; Four-/six-wire wiring, excitation needs and cable length; Minimum load, required division and update response; Analogue or digital interface and control-system mapping; Environment, shielding, supply and metrological use. Mark unknown items for confirmation instead of substituting a normal point or an assumed default for all conditions.
Verification: Have process, instrumentation and purchasing roles agree the inputs, particularly "Four-/six-wire wiring, excitation needs and cable length". Resolve missing evidence before requesting application confirmation.
适用边界:ADC bits and display divisions do not establish usable accuracy or stable resolution
4How should the range be chosen rather than copied from a nominal equipment rating?
Select the range from actual operating conditions and permissible error, then check extremes and installation constraints. For this family: ADC bits and display divisions do not establish usable accuracy or stable resolution Nominal size or maximum equipment rating need not equal the useful measuring interval.
Verification: List minimum, normal, maximum and abnormal conditions. Check "Minimum load, required division and update response" against the documented performance envelope.
适用边界:ADC bits and display divisions do not establish usable accuracy or stable resolution
5Can a larger turndown claim or display rescaling fix poor low-end performance?
No. Low-end usability depends on the principle, available signal and error mechanisms. Parallel bridge excitation load must stay within indicator capability More display digits, software scaling or a stated turndown cannot remove the original noise or installation error.
Verification: Obtain error definitions and limits at the actual low operating point. Use "Scale error: inspect capacity, mV/V and unit settings" to investigate bias instead of comparing only percent-of-full-scale values.
适用边界:Parallel bridge excitation load must stay within indicator capability
6How should compatibility with the measured object and materials be established?
Use the complete measured object and actual exposure, rather than a material name alone. Analogue or digital interface and control-system mapping Avoid this family-specific misuse: Treating net-weight tare as extra load capacity For non-wetted equipment, assess loads, target materials, signals and environmental compatibility instead.
Verification: List the actual contact or loading parts, seals, insulation and cleaning conditions. Have the responsible parties assess "Tare changes the indication baseline but not mechanical/electrical capacity".
适用边界:Tare changes the indication baseline but not mechanical/electrical capacity
7Why must abnormal and environmental conditions be listed separately from normal operation?
Normal measurement, temporary excursions and survival limits are different requirements. Tare changes the indication baseline but not mechanical/electrical capacity Start-up, cleaning, impacts, power interruption or abnormal environments can determine the necessary construction and protection.
Verification: Complete the worst-case conditions using "Environment, shielding, supply and metrological use" and check "Electrical calibration does not establish load-path or legal-metrology performance". Separate continuous operating limits from temporary limits in the specification.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance
8Can the published instrument accuracy be used as the installed system accuracy?
Not without assessment. Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately. The installed system also includes object, mounting, signal conversion, environmental and reference effects. Derived results additionally depend on the relevant input uncertainties.
Verification: Agree actual test points, installation conditions and the acceptance reference. Check "Wire bridge and sense terminals correctly and check total load" and document the system error or uncertainty basis.
适用边界:Parallel bridge excitation load must stay within indicator capability
9How should response time, filtering and a stable display be balanced?
A stable indication and fast change detection involve a trade-off; filtering cannot repair incorrect installation or real process variation. Jitter: inspect vibration, wiring, bridge loading and filtering Review the complete chain when fast response matters, not merely the display refresh rate.
Verification: Define the shortest relevant event and acceptable delay. Check "Retain raw mV/V before setting capacity, sensitivity, zero and span" and verify local output, display and receiving-system response using a controlled change.
适用边界:Replacing mechanical calibration with shunt or digital simulation
10Which typical applications fit, and which require a specific engineering review?
Typical contexts include: Hopper-weighing signal processing; Platform-scale indication and controls; Weight transmission for batching systems. Similar application labels do not establish equivalent conditions. In particular, assess "Electrical calibration does not establish load-path or legal-metrology performance" before relying on another installation as proof.
Verification: Select the nearest application and compare "Number of cells, bridge resistance, mV/V and nominal capacities" and "Environment, shielding, supply and metrological use". Obtain written confirmation where published application limits are exceeded.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance
11How should a complete order code be defined without unspecified standard options?
Translate required functions, performance and physical interfaces into verifiable options. Input mV/V range, zero balance and bridge excitation capacity; Cell count, bridge resistance and wiring compatibility. Options affecting suitability or supply scope should be explicit; terms such as standard or same as existing are insufficient.
Verification: Check the complete order code and selection sheet, especially "Minimum load, required division and update response". List accessories, documents, calibration and delivery boundaries separately.
适用边界:Promising effective resolution directly from a 24-bit label
12Which mounting and mechanical layout checks belong before ordering?
Wire bridge and sense terminals correctly and check total load The installation drawing must match the available space and process or mechanical structure. Access for fitting and servicing should be established before delivery.
Verification: Review a dimensioned, oriented site drawing. Use "Analogue or digital interface and control-system mapping" and "Tare changes the indication baseline but not mechanical/electrical capacity" to confirm connections, support, removal access and safe isolation.
适用边界:Tare changes the indication baseline but not mechanical/electrical capacity
13How can supporting infrastructure prevent an instrument that fits but cannot be used?
Separate microvolt signals from drives and review shielding/grounding Supporting conditions are part of the measurement system. Matching mechanical connections or signal names alone do not establish power, I/O, grounding or configuration compatibility.
Verification: Confirm "Output types, scaling, protocol and updates" and "Filtering, tare, zero tracking and alarm behaviour" against actual terminals, loops and receiving-system settings.
适用边界:Treating net-weight tare as extra load capacity
14What is a sensible commissioning sequence before changing correction factors?
Check identity, installation and basic conditions first, then status, output and process response. Retain raw mV/V before setting capacity, sensitivity, zero and span Preserve original evidence for unexplained anomalies instead of concealing them with zero or factor adjustments.
Verification: Record factory settings and initial status. Investigate "No load indication: inspect excitation, signal/sense wiring and input status" step by step and change parameters only after identifying the cause and using an authorised procedure.
适用边界:Replacing mechanical calibration with shunt or digital simulation
15Do identical output units or interface names establish connection compatibility?
No. Establish the represented object and reference conditions: Input mV/V range, zero balance and bridge excitation capacity. Electrical equipment also needs loop type, scaling, failure behaviour and protocol details checked. Mechanical indicators require clear boundaries between indication and remote-transmission accessories.
Verification: Check the receiving-system variable against "Number of cells, bridge resistance, mV/V and nominal capacities" and verify limits, units and abnormal states with the actual equipment. Record wiring, configuration and end-to-end checks against "Separate microvolt signals from drives and review shielding/grounding".
适用边界:Treating net-weight tare as extra load capacity
16What should a calibration report contain to be relevant to the application?
Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately. The report should identify the delivered instrument, measured quantity, conditions, method and results. A general conformity certificate does not establish performance for every option or operating condition.
Verification: Check serial number, points, units, reference equipment and traceability. Compare "Four-/six-wire wiring, excitation needs and cable length" with the calibrated conditions and agree separate acceptance where they differ.
适用边界:Parallel bridge excitation load must stay within indicator capability
17How can delivery and site acceptance use reproducible pass criteria?
Use actual reference loads to verify indication, communication, analogue output and alarms Agree criteria before testing, including range, conditions, error definition and treatment of anomalies. Similar-looking readings or an unsuitable portable reference are not sufficient acceptance evidence.
Verification: Choose an appropriate reference using "Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately.". Record "Number of cells, bridge resistance, mV/V and nominal capacities" and test conditions; investigate "Scale error: inspect capacity, mV/V and unit settings" before deciding on rework or recalibration.
适用边界:Parallel bridge excitation load must stay within indicator capability
18What belongs in the quotation and agreement for a non-standard application?
Define why the standard supply is insufficient, the required verification and the responsible parties. Electrical calibration does not establish load-path or legal-metrology performance; Ignoring excitation capability and individual failures in parallel cells. Additional materials, construction, documents or tests depend on actual requirements.
Verification: Attach "Environment, shielding, supply and metrological use" and the deviations. Obtain technical confirmation, additional charges, delivery conditions and acceptance methods; unknown requirements must not be assumed satisfied.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance
19Where should investigation start when there is no valid reading or output?
No load indication: inspect excitation, signal/sense wiring and input status Distinguish the actual measured condition from device-state and readout or transmission faults. Do not immediately interpret missing data as sensor failure or a zero process value.
Verification: Under appropriate safe isolation, check "Separate microvolt signals from drives and review shielding/grounding". Compare local and receiving-end status and record when the fault appeared.
适用边界:Promising effective resolution directly from a 24-bit label
20How can unstable readings be separated from genuine process variation?
Jitter: inspect vibration, wiring, bridge loading and filtering Compare independent process evidence and raw signals before deciding whether installation, interference or equipment is responsible. More filtering can hide a real abnormal event.
Verification: Keep conditions comparable and record correlation with process or equipment events. Check "Wire bridge and sense terminals correctly and check total load" and change one factor at a time.
适用边界:Replacing mechanical calibration with shunt or digital simulation
21How should a persistent high or low bias be investigated before changing factors?
Scale error: inspect capacity, mV/V and unit settings Systematic bias can arise from units, reference conditions, configuration, installation or the reference method. An unexplained correction can move one operating-point error to other conditions.
Verification: Align quantities, time bases and units first. Review the reference using "Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately." and confirm that "Four-/six-wire wiring, excitation needs and cable length" matches the configuration.
适用边界:Parallel bridge excitation load must stay within indicator capability
22When is it appropriate to adjust a drifting zero or reference position?
Slow zero change: separate raw bridge, temperature and automatic zero tracking Establish a genuine, stable reference condition that meets the method requirements before considering adjustment. Some instruments have no freely adjustable site zero.
Verification: Check "Retain raw mV/V before setting capacity, sensitivity, zero and span" and "Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately." and retain before-and-after results. If the conditions cannot be established, remove external effects or use a qualified service.
适用边界:Replacing mechanical calibration with shunt or digital simulation
23Which evidence helps diagnose intermittent alarms or failures?
Local/remote mismatch: inspect scaling, byte order and units Intermittent faults need correlated event records, not just a normal display after recovery. Review alarm settings, communication status and actual process abnormalities separately.
Verification: Retain time, status codes, raw trends and the contemporaneous "Environment, shielding, supply and metrological use". Compare "Separate microvolt signals from drives and review shielding/grounding" and "Retain raw mV/V before setting capacity, sensitivity, zero and span" to locate the failing link.
适用边界:Ignoring excitation capability and individual failures in parallel cells
24Why should repeated failures trigger a cause review instead of another identical replacement?
Repeated failures warrant a common-cause assessment. Ignoring excitation capability and individual failures in parallel cells If the external conditions remain unchanged, an identical construction or installation can experience the same failure again.
Verification: Summarise failed parts, service time and "Environment, shielding, supply and metrological use". Check "Wire bridge and sense terminals correctly and check total load" and "Tare changes the indication baseline but not mechanical/electrical capacity" and establish corrective action before selecting repair or redesign.
适用边界:Tare changes the indication baseline but not mechanical/electrical capacity
25What distinguishes a site comparison, an adjustment and a calibration?
Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately. A comparison identifies differences; adjustment changes indication or parameters; calibration establishes a reference relationship under stated conditions. They are not interchangeable claims.
Verification: Define what performance and evidence must be established, using conditions relevant to "Four-/six-wire wiring, excitation needs and cable length". Retain original and adjusted results, references and responsibility records.
适用边界:Parallel bridge excitation load must stay within indicator capability
26What must be checked again after replacing an instrument with the same basic model?
The same basic model does not establish identical options, software, calibration or accessories. Filtering, tare, zero tracking and alarm behaviour; Metrological or hazardous-area documents for the complete application. Previous system operation does not remove the need to verify a replacement.
Verification: Compare full order codes and revisions. Recheck critical points, failure states and interfaces using "Use actual reference loads to verify indication, communication, analogue output and alarms" before handover.
适用边界:Ignoring excitation capability and individual failures in parallel cells
27Can every published maximum rating be achieved simultaneously?
No. ADC bits and display divisions do not establish usable accuracy or stable resolution Maximum values usually relate to particular options and conditions. Temperature, load, pressure, materials, speed or signal conditions may constrain one another.
Verification: Review "Minimum load, required division and update response" and "Environment, shielding, supply and metrological use" together. Obtain confirmation for the combined conditions instead of assembling unrelated maxima from separate pages.
适用边界:ADC bits and display divisions do not establish usable accuracy or stable resolution
28Does a missing signal or zero indication establish that the process value is zero?
No. No load indication: inspect excitation, signal/sense wiring and input status Indication, measurement and transmission have distinct possible failure modes. Also consider "Promising effective resolution directly from a 24-bit label"; establish the actual process condition independently.
Verification: Check available status or failure indications and "Output types, scaling, protocol and updates". For interlocks, follow the complete safety design rather than substituting a zero value for diagnosis.
适用边界:Promising effective resolution directly from a 24-bit label
29Does one acceptable test point establish compliance across the working range?
No. Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately. Test points and directions must reflect the working interval, relevant error mechanisms and acceptance purpose. Multiple points, reversal or load tests depend on the method.
Verification: Define acceptance coverage against "Four-/six-wire wiring, excitation needs and cable length" and include critical operating points. Mark conditions outside the tests as unverified.
适用边界:Parallel bridge excitation load must stay within indicator capability
30Are the largest range, highest accuracy class and most options always preferable?
Not necessarily. Options should serve the required objective; excess configuration can add cost, complexity or incompatibility. Parallel bridge excitation load must stay within indicator capability; Treating net-weight tare as extra load capacity. Establish essential requirements before comparing optional benefits.
Verification: Document the objective in "Number of cells, bridge resistance, mV/V and nominal capacities" and why "Input mV/V range, zero balance and bridge excitation capacity" is needed. Compare performance at actual working points rather than one headline metric.
适用边界:Parallel bridge excitation load must stay within indicator capability
31Can every maintenance or recalibration interval simply be fixed at one year?
Not independently of risk and history. Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately. Intervals depend on applicable law or contract, conditions, drift, maintenance and failure evidence. Generic advice cannot replace mandatory requirements.
Verification: Use "Slow zero change: separate raw bridge, temperature and automatic zero tracking" and "Ignoring excitation capability and individual failures in parallel cells" to establish and review an initial plan. Retain the justification and approval for interval changes.
适用边界:Ignoring excitation capability and individual failures in parallel cells
32Can parts from different brands be mixed if their physical interfaces fit?
Physical fit is insufficient. Cell count, bridge resistance and wiring compatibility; Output types, scaling, protocol and updates. Matching, materials, signals, calibration and approval boundaries can change with the combination.
Verification: Check the complete combination against "Separate microvolt signals from drives and review shielding/grounding" and obtain compatibility and acceptance evidence. An unconfirmed assembly must not be described as an approved system.
适用边界:Treating net-weight tare as extra load capacity
33Does a hazardous-area, hygienic or safety label establish suitability for that duty?
Check the exact order configuration and valid documents rather than a series name. Metrological or hazardous-area documents for the complete application "Electrical calibration does not establish load-path or legal-metrology performance" also matters; certificates, installation conditions and restrictions together define suitability.
Verification: Obtain certificate identifiers, covered models and special conditions and match them to the site. Similar names do not grant functional-safety or legal-metrology approval.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance
34What evidence makes the final result acceptable, reproducible and sustainable?
Establish the chain from quantity definition and application limits through configuration, mounting, reference and operating status. Use actual reference loads to verify indication, communication, analogue output and alarms A normal indication or brochure alone cannot demonstrate continuing system reliability.
Verification: Put "Number of cells, bridge resistance, mV/V and nominal capacities", "Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately." and "Local/remote mismatch: inspect scaling, byte order and units" into the technical, acceptance and maintenance records, with responsibility for reviewing excursions.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance
35Can a DOWESTON model replace an installed instrument from another brand?
Possibly, after a full configuration and application comparison. A basic model name or matching output is not proof of equivalent replacement. Input mV/V range, zero balance and bridge excitation capacity; Cell count, bridge resistance and wiring compatibility; Output types, scaling, protocol and updates. Record conclusions on material differences.
Verification: Provide the original full order code, data sheet and site conditions. Check "Filtering, tare, zero tracking and alarm behaviour" and "Metrological or hazardous-area documents for the complete application" and obtain the necessary test and approval evidence before replacement.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance
36Why choose DOWESTON, and what would make that reasoning evidence-based?
Base the decision on project compliance and documented delivery or service, rather than a slogan. "Number of cells, bridge resistance, mV/V and nominal capacities" and "ADC bits and display divisions do not establish usable accuracy or stable resolution" are important family-specific checks. Claim only benefits supported by the offered product documents and written commitments.
Verification: Request the proposed configuration matching "Input mV/V range, zero balance and bridge excitation capacity", test evidence and delivery/service terms. Do not infer unverified performance, approvals, origin or service life.
适用边界:ADC bits and display divisions do not establish usable accuracy or stable resolution
37How can competing brands be compared beyond a single accuracy or price figure?
Use identical conditions and supply boundaries. Input mV/V range, zero balance and bridge excitation capacity; Output types, scaling, protocol and updates; Metrological or hazardous-area documents for the complete application. Quotes with different ranges, compensation, accessories or calibration scope can conceal material differences.
Verification: Compare "Four-/six-wire wiring, excitation needs and cable length", "Parallel bridge excitation load must stay within indicator capability" and mounting/acceptance conditions. Separate demonstrated, unverified and inapplicable items; do not claim unproven overall superiority.
适用边界:Parallel bridge excitation load must stay within indicator capability
38How should purchasing compare cost without overlooking additions or rework?
Compare complete supply and use-cycle costs, not only the main instrument price. Wire bridge and sense terminals correctly and check total load; Verify electrical conversion with a traceable bridge simulator and the installed system with reference loads; compare digital/analogue outputs with indication separately. List the actual installation, supporting equipment, calibration, consumables, downtime and service requirements without assuming any brand is always cheaper.
Verification: Use the same "Input mV/V range, zero balance and bridge excitation capacity" configuration and "Environment, shielding, supply and metrological use" boundary. Separate equipment, accessories, commissioning and maintenance responsibilities and retain a traceable comparison.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance
39Does a 24-bit ADC imply sixteen million stable weight divisions?
No. Noise, input range, excitation, drift and mechanics limit usable resolution; display digits can be smoothed or interpolated. Assess the actual system.
Verification: Record unloaded and reference-load stability at actual installation, speed and temperature conditions.
适用边界:ADC bits and display divisions do not establish usable accuracy or stable resolution
40How is the supported number of 350-ohm cells determined?
Parallel cells reduce equivalent resistance and increase excitation current; cable and sensing capability also matter. Use the model’s documented minimum load and excitation ratings.
Verification: Calculate total resistance and check excitation and far-end voltage against permitted capability.
适用边界:Parallel bridge excitation load must stay within indicator capability
41Can six-wire sense leads be arbitrarily linked to excitation?
Sense leads support specified compensation for actual bridge excitation; the link location affects it. Use only the documented four-wire arrangement if supported.
Verification: Confirm sense termination on the full diagram and recheck zero, span and temperature effects after changes.
适用边界:Tare changes the indication baseline but not mechanical/electrical capacity
42Why is applied loading needed after entering nominal mV/V and capacity?
Nominal sensitivity may differ from the individual value, while bypass and load distribution add system effects. Numeric setup establishes a model, not proof of installed weighing.
Verification: Apply reference loads across the working interval and retain individual calibration and installation details.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance
43Does tare allow additional load beyond rated capacity?
No. Tare changes the display baseline while the sensor and electronics still carry gross load. Ignoring it can cause mechanical overload or electrical saturation.
Verification: Check maximum gross load and raw mV/V headroom and document net, tare and capacity.
适用边界:ADC bits and display divisions do not establish usable accuracy or stable resolution
44Can automatic zero tracking suppress slowly added material?
Depending on its window and algorithm, zero tracking can alter the baseline during slow changes. Review the actual implementation for slow dosing.
Verification: Test the slowest intended dosing rate with tracking states compared and retain raw trends.
适用边界:Parallel bridge excitation load must stay within indicator capability
45Why can local weight be correct while the PLC value is wrong?
Register format, byte order, decimal scale, units or analogue scaling may differ. Check raw data at every stage instead of comparing displays alone.
Verification: Record raw registers/current and PLC values at zero, middle and high loads and align mapping.
适用边界:Tare changes the indication baseline but not mechanical/electrical capacity
46Why can heavy filtering affect a batch cutoff?
Filtering delays the indicated change; cutoff can lag actual loading, and material in flight or actuator delay can increase overshoot. Stable display and dynamic control are different goals.
Verification: Record raw/filtered values, cutoff output and final weight at actual dosing speed.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance
47Why can a parallel-cell fault still produce a plausible total value?
Remaining bridges can continue producing a plausible combined signal. An individual fault need not force an obvious overrange; review per-cell diagnostics where needed.
Verification: Verify detectable faults and support-inspection procedures in an approved test, not by arbitrary live disconnection.
适用边界:ADC bits and display divisions do not establish usable accuracy or stable resolution
48Should zero be reset before checking raw mV/V drift?
Retain raw bridge signal and state first to distinguish force, sensor drift and processing. Immediate zeroing can hide binding or residual material.
Verification: Record unloaded conditions, temperature, raw mV/V and tracking state before corrective action.
适用边界:Parallel bridge excitation load must stay within indicator capability
49Does a bridge simulator prove both analogue and digital outputs are correct?
Only outputs actually checked are verified. Correct input indication does not prove D/A mapping, registers or communication scaling; test each path.
Verification: Record indication, current, registers and alarm action at the same input points and check units.
适用边界:Tare changes the indication baseline but not mechanical/electrical capacity
50Does an existing scale approval automatically remain valid after replacing its indicator?
Not automatically. Approval can constrain indicator, cells, divisions and permitted combinations. A working display does not establish continued legal-metrology conformity.
Verification: Review approval conditions and obtain qualified confirmation of verification requirements after the change.
适用边界:Electrical calibration does not establish load-path or legal-metrology performance






