How to specify minimum, normal and maximum flow

Separate stopped flow, low-flow production, normal operation and peaks instead of using one number for every condition.

Minimum flow is not the stopped condition

Specify the lowest production flow that still needs valid measurement, such as a recirculation loop, small batch or slow transfer. Describe stopped flow separately. If start-up and shutdown must also be measured, record their flow rates, durations and whether the measuring section remains full.

Normal flow describes the main operating condition

Normal flow is the most common operating point or range; it is not automatically half the maximum. If recipes, batches or seasons differ substantially, provide several typical points and their share of operating time so that comparisons represent real use.

  • For a continuous process, provide a representative flow trend.
  • For batching, provide the flow profile over time and the target batch quantity.

Separate sustained maximum from short peaks

State the maximum continuous flow and any brief peaks, such as start-up surges. Do not treat a peak as a sustained condition or disregard it solely because it is short. Check pressure loss, velocity and output range at the peak; short batches also require consideration of response and totalisation.

Use consistent units and reference conditions

An example worksheet might list minimum 100 kg/h, normal 1000 kg/h and continuous maximum 2000 kg/h, with peaks recorded separately. These are illustrative entries, not a meter rating. Gas volume needs actual or standard conditions and the reference temperature and pressure. Converting liquid volume to mass requires the density used and its associated temperature.

Apply this knowledge to product selection

Customers and procurement

Check actual application and acceptance requirements against the article and product documentation. Bring open questions to DOWESTON for technical review.

Sales and technical teams

Record customer questions with application conditions. Verify range, interfaces and operating requirements against the selected model documentation.

Turn questions into application requirements

Collect application, connection, installation and acceptance requirements for the selected product, then review open points with DOWESTON.

Choose a product and prepare requirements
لم تسجّل الدخول إلى DOWESTON؟
أنشئ حساباً لبدء الاختيار والاطلاع على الأسعار وتلقّي نشرتنا الإلكترونية بأحدث المنتجات والاتجاهات.
المنتجات والخدمات
تقدم Doweston مجموعة خدمات لمساعدتك في بناء أنظمة القياس الآلية بسرعة. تواصل معنا لمعرفة المزيد.
هل أنت مستعد للشراء؟
إ كنت ترغب في شراء المنتجات،
فما عليك سوى التواصل مع فريق المبيعات — يسعدنا مساعدتك.
من نحن
تقدم DOWESTON حلول قياس دقيقة وموثوقة
— منتجات استشعار وكشف موثوقة في جميع المجالات!
هل لديك طلب خدمة؟
إذا كنت ترغب في تحسين الإنتاج وتقليل فترات التوقف،
يمكننا مساعدتك في اختيار قطع الغيار وخدمات ما بعد البيع المناسبة.
تعديل بيانات التكوين

المنتج

العلامة التجارية

الطراز

تأكيد التعديل إلغاء
قد تكون شاشتك صغيرة جداً لتجربة مريحة.
ننصح بمتابعة استخدام حاسوب،
أو تواصل فوراً مع مهندس لاختيار المنتج المناسب!
خدمة أسرع؟ اتصل على
400-888-4436
متابعة التصفح